2020
DOI: 10.1016/s2352-4642(20)30183-8
|View full text |Cite
|
Sign up to set email alerts
|

The SIOP-Renal Tumour Study Group consensus statement on flank target volume delineation for highly conformal radiotherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
39
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 28 publications
(39 citation statements)
references
References 25 publications
0
39
0
Order By: Relevance
“…To our knowledge, this is the first cohort of pediatric patients with a renal tumor that describes the locoregional outcome of highly conformal flank irradiation using new target volumes adjusted for postoperative organ shifts and optimized by the use of surgical clips and 4D-CT scans [17,21]. After a median followup of 3.1 years, two patients developed a locoregional relapse resulting in a 2-year LCR of 94%, which is in line with the reported number of locoregional events observed in patients with stage III WT treated by the use of a conventional technique within the SIOP-2001 and AREN0532 studies [4,25].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…To our knowledge, this is the first cohort of pediatric patients with a renal tumor that describes the locoregional outcome of highly conformal flank irradiation using new target volumes adjusted for postoperative organ shifts and optimized by the use of surgical clips and 4D-CT scans [17,21]. After a median followup of 3.1 years, two patients developed a locoregional relapse resulting in a 2-year LCR of 94%, which is in line with the reported number of locoregional events observed in patients with stage III WT treated by the use of a conventional technique within the SIOP-2001 and AREN0532 studies [4,25].…”
Section: Discussionmentioning
confidence: 99%
“…For target volume delineation, the lateral clip was used to determine the lateral tumor extension, while the superior clip was used to capture the intra-fraction motion of the tumor bed, as described in a previous report [21]. Gross Tumor Volumes (GTV) and Clinical Target Volumes (CTV) were corrected for the postoperative changes in anatomy, in line with the SIOP-RSTG consensus statement on highly conformal flank target volume delineation [17]. An Internal Target Volume (ITV) margin, defined as the maximum intra-fraction motion registered by the 4D-CTscan, was used to expand the CTV.…”
Section: Highly Conformal Flank Irradiationmentioning
confidence: 99%
See 2 more Smart Citations
“…Radiotherapy (IGRT) techniques that allow high-precision dose delivery to complex target volumes. Prompted by this development, radiation oncologists affiliated to the SIOP-RTSG reached consensus on a highly-conformal target volume definition for flank irradiation: it was hypothesized that intraperitoneal tumor recurrence is unlikely in patients without major tumor rupture [7]. This was based on the fact that renal tumors are covered by a peritoneal lining and push aside, rather than invade, the intraperitoneal organs and abdominal wall.…”
Section: Discussionmentioning
confidence: 99%