2002
DOI: 10.1007/s003390101091
|View full text |Cite
|
Sign up to set email alerts
|

The small angle neutron spectrometer at the HANARO reactor, Korea

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2004
2004
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…SANS experiments were also performed to characterize nano-precipitates in the steels at room temperature at the HANARO Cold Neutron facility [ 24 ] which is equipped with a two-dimensional position sensitive detector. Flat samples with the dimensions of 5 × 2.2 × 1.5 mm were placed between the two electric magnetic poles, where the external magnetic field (1.0 T) was applied horizontally, parallel to the sample surface, and perpendicular to the incident neutron beam.…”
Section: Methodsmentioning
confidence: 99%
“…SANS experiments were also performed to characterize nano-precipitates in the steels at room temperature at the HANARO Cold Neutron facility [ 24 ] which is equipped with a two-dimensional position sensitive detector. Flat samples with the dimensions of 5 × 2.2 × 1.5 mm were placed between the two electric magnetic poles, where the external magnetic field (1.0 T) was applied horizontally, parallel to the sample surface, and perpendicular to the incident neutron beam.…”
Section: Methodsmentioning
confidence: 99%
“…The SANS experiments with a magnetic field of 1.0 Tesla were performed the HANARO Reactor [10]. The wavelength (λ) used was 0.508 nm, the sample-to-detector distance was 3.0 m and the wavelength spread ( λ/λ) was about 12%.…”
Section: Methodsmentioning
confidence: 99%
“…Two-dimensional scattering patterns collected by the two-dimensional area detectors with an active area of 64.5 × 64.5 cm 2 were averaged to produce a one-dimensional intensity profile. Calibration to absolute SANS cross section was obtained by measurement of standard porous silica in a 1 mm path-length quartz cell [10]. The data were treated by ILL standard programs [11].…”
Section: Methodsmentioning
confidence: 99%
“…The RPV steel was irradiated in the HANARO reactor at KAERI with a fluence of 2.5x10 19 n/cm 2 at 290 o C. This RPV steel is used at the YeongKwang nuclear power plant. The small angle neutron scattering experiments were performed at the SANS instrument in the HANARO reactor at KAERI [5]. The experimental set-ups included a wavelength of 4.31Å with a wavelength spread(FWHM) of 12% and the sample to detector distance of 2m from the SANS instrument at KAERI.…”
Section: Methodsmentioning
confidence: 99%