1984
DOI: 10.1136/bjo.68.4.235
|View full text |Cite
|
Sign up to set email alerts
|

The SRK regression formula in calculating the dioptric power of intraocular lenses.

Abstract: SUMMARY One hundred and seventy one eyes with intraocular lenses were studied to compare the predictive accuracy of the Fyodorov and Van der Heijde theoretical formulae of the SandersRetzlaff-Kraff (SRK) regression formula. The SRK regression formula was the most accurate. Our personal calculations of the A constants of this formula are given for several types of implants and manufacturers.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

1988
1988
2024
2024

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 5 publications
1
6
0
Order By: Relevance
“…On the other hand, about one-third of the eyes had unexpected postoperative ametropias > 2 l.OD, and about 10% of the cases deviated more than k 2.OD from the predicted refraction. These results were similar to or better than those published by Menezo et al (1984), Richards et al (1985), Hope-Ross & Mooney (1988) and Spitznas et al (1991), while better accuracies have been reported by among others Dang & Raj (1989) and Sanders et al (1990). However, bearing in mind the large number of doctors taking part in the pre-and postoperative examinations, a more optimal performance of the calculation formulas in the present study could not realistically be expected.…”
Section: Discussionsupporting
confidence: 86%
“…On the other hand, about one-third of the eyes had unexpected postoperative ametropias > 2 l.OD, and about 10% of the cases deviated more than k 2.OD from the predicted refraction. These results were similar to or better than those published by Menezo et al (1984), Richards et al (1985), Hope-Ross & Mooney (1988) and Spitznas et al (1991), while better accuracies have been reported by among others Dang & Raj (1989) and Sanders et al (1990). However, bearing in mind the large number of doctors taking part in the pre-and postoperative examinations, a more optimal performance of the calculation formulas in the present study could not realistically be expected.…”
Section: Discussionsupporting
confidence: 86%
“…The regression formulas, especially the SRK one, are the ones widely used in calculat ing the power of IOL [14][15][16]. In our series, the regression formulas (SRK, DKG and Axt) have proved to be more accurate than the the oretical formulas, with good average devia tions, small maximum deviations, and the greatest percentage of cases with a predictive error within 1.0 dptr.…”
Section: Discussionmentioning
confidence: 86%
“…In the second part of this study of anterior chamber implants we focused our attention on the empirical SRK formulas (SRK and SRK II) mainly because they are highly accurate, widely utilised, and their 'A' constants can be readily optimised unlike the constants used by the theoretical formulas.`1 3-17 [21][22][23][24][25][26][27][28] We did not evaluate the recently developed SRK/T formula'9 which is a combination of the empirical and theoretical approaches because (i) at present it is neither readily available nor widely used, (ii) it was not superior to the more commonly used SRK II formula except in eyes of axial length >28-4 mm,9 and eyes of this axial length were not encountered in this study population.…”
Section: Discussionmentioning
confidence: 99%