Lawrie's Meat Science 2023
DOI: 10.1016/b978-0-323-85408-5.00013-3
|View full text |Cite
|
Sign up to set email alerts
|

The storage and preservation of meat: II—Nonthermal technologies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
0
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 99 publications
0
0
0
Order By: Relevance
“…Gamma ray is the electromagnetic wave emitted from the radioactive material. It has a high-energy and penetration ability, which can reach a depth of 80 cm ( Ahn et al, 2023 ). The electron beam is the high energy accelerated electron, emitted from the ionized radioactive material.…”
Section: The Types Of Radiation and Mechanism Of Irradiation Technologymentioning
confidence: 99%
See 2 more Smart Citations
“…Gamma ray is the electromagnetic wave emitted from the radioactive material. It has a high-energy and penetration ability, which can reach a depth of 80 cm ( Ahn et al, 2023 ). The electron beam is the high energy accelerated electron, emitted from the ionized radioactive material.…”
Section: The Types Of Radiation and Mechanism Of Irradiation Technologymentioning
confidence: 99%
“…In contrast, the gamma ray and X-ray are electromagnetic waves, which transfer a portion of their energy to the electrons of the atoms in the food ( Jia et al, 2022 ). This excitation of electrons results in their exit from the orbits ( Ahn et al, 2023 ). These electrons continually excite and ionize atoms in food, until the energy remains sufficient to cause these reactions.…”
Section: The Types Of Radiation and Mechanism Of Irradiation Technologymentioning
confidence: 99%
See 1 more Smart Citation
“…A first cream batch was subjected to 450 MPa and 600 MPa for 5 min each, at 7 • C, to optimize the pressure level required to achieve desirable microbial inactiva-tion levels to extend the shelf life of dairy cream. Additionally, as described in the literature, the temperature of water increases between 2 and 3 • C for each 100 MPa [13]; so, in order to have a maximum temperature of 19-25 • C while at 600 MPa, the water temperature before pressurization was 7 • C. A second cream batch was processed at 600 MPa for 5 and 15 min at 7 • C to evaluate the effects of the processing time (at the most suitable pressure obtained in the first batch) on dairy cream. After the respective processing, samples from both batches were stored at 4 • C.…”
Section: Hpp Treatment Of Samplesmentioning
confidence: 99%