2019
DOI: 10.1016/j.renene.2019.01.129
|View full text |Cite
|
Sign up to set email alerts
|

The study and application of evaluation methods for photovoltaic modules under real operational conditions, in a region of the Brazilian Southeast

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 12 publications
0
9
0
2
Order By: Relevance
“…The determination of the coefficients 𝑎, 𝑅 𝑠 and 𝜅 for M1 and M2 requires a group of I-V curves at the same G or at the same Tm, which is troublesome and time-consuming to fulfill in real life. Therefore, in most M1 and M2 applications, these coefficients are either tuned via simulation under healthy condition (Silva et al, 2019) or neglected (Dolara et al, 2013) but to the detriment of lower performance. Therefore, in this paper, these coefficients will not be neglected and determined following the standard routine, i.e., via the simulation under healthy condition.…”
Section: Correction Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The determination of the coefficients 𝑎, 𝑅 𝑠 and 𝜅 for M1 and M2 requires a group of I-V curves at the same G or at the same Tm, which is troublesome and time-consuming to fulfill in real life. Therefore, in most M1 and M2 applications, these coefficients are either tuned via simulation under healthy condition (Silva et al, 2019) or neglected (Dolara et al, 2013) but to the detriment of lower performance. Therefore, in this paper, these coefficients will not be neglected and determined following the standard routine, i.e., via the simulation under healthy condition.…”
Section: Correction Methodsmentioning
confidence: 99%
“…Based on the corrected curves, the open-circuit voltage (𝑉 𝑂𝐶 ), shortcircuit current (𝐼 𝑆𝐶 ), the voltage at the point of maximum power (𝑉 𝑀𝑃𝑃 ), current (𝐼 𝑀𝑃𝑃 ) and power (𝑃 𝑚 ) are commonly extracted characteristics for fault diagnosis (Agrawal et al, 2020;Chen et al, 2017;Huang et al, 2019) or power loss analysis (Wang et al, 2020). Besides, equivalent series resistance (𝑅 𝑠 ) or shunt resistance (𝑅 𝑠ℎ ) are also commonly calculated from corrected curves to analyze the degradation mode of PV networks (Bouaichi et al, 2019;Silva et al, 2019).…”
Section: Introductionmentioning
confidence: 99%
“…The temperature sensor employed is the DS18B20 with an operational range between −55 • C to 125 • C with accuracy of ±0.5 • C. This sensor uses the One Wire protocol for communicating data and possesses a waterproof covering. In order to obtain the cell temperature, Equation ( 5) is used, where T cel is the operational temperature of the cell, T amb is the environment temperature, NOCT is the nominal operational temperature of the cell and G is the irradiance [23].…”
Section: Methodsmentioning
confidence: 99%
“…According to manufacturers, a PV module is degraded when its power reaches a level below 80% of its initial power. When this occurs, the PV modules operate outside the expected quality limits, therefore negatively impacting on the performance, and subsequently increasing costs, as well as reducing the working life of the panel (Silva, Melo, Reis, & Freitas, 2019). Temperature, humidity and UV radiation are the main environmental parameters that could degrade the PV modules.…”
Section: Degradation In Pv Modulesmentioning
confidence: 99%