2015
DOI: 10.1016/j.ejso.2014.11.006
|View full text |Cite
|
Sign up to set email alerts
|

The superparamagnetic iron oxide is equivalent to the Tc99 radiotracer method for identifying the sentinel lymph node in breast cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
103
0
10

Year Published

2016
2016
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 118 publications
(120 citation statements)
references
References 23 publications
7
103
0
10
Order By: Relevance
“…Hence, these directionality evaluations indicate that the cone-type magnet has a better directionality compared to the column-type magnet. Although the directionality of the magnetic with the permanent magnet is not comparable to that of conventional gamma probes, 10,11 these results show that the sharply pointed shape of the magnet leads to the enhancement of the directionality.…”
Section: Resultsmentioning
confidence: 79%
See 1 more Smart Citation
“…Hence, these directionality evaluations indicate that the cone-type magnet has a better directionality compared to the column-type magnet. Although the directionality of the magnetic with the permanent magnet is not comparable to that of conventional gamma probes, 10,11 these results show that the sharply pointed shape of the magnet leads to the enhancement of the directionality.…”
Section: Resultsmentioning
confidence: 79%
“…Recent studies [7][8][9][10] have shown that the magnetic technique using superparamagnetic iron oxide (SPIO) nanoparticles and a handheld magnetic probe can be alternatives to the radioisotope technique as a noninvasive and promising method, particularly for hospitals with no radiation facility. In order to detect the SLNs in vivo by transcutaneous measurements, detectable distance of 12 ± 5 mm of the magnetic probe is required 11 at least.…”
Section: Introductionmentioning
confidence: 99%
“…The sentinel node detection rates per patient range from 94.4 to 98% [8,9,10,11,12,13,14]. A recent meta-analysis [14] including 7 non-randomised studies [8,9,10,11,12,13,14]showed that Sienna+ is non-inferior to standard mapping techniques for sentinel node detection.…”
Section: Superparamagnetic Iron Oxidementioning
confidence: 99%
“…A recent meta-analysis [14] including 7 non-randomised studies [8,9,10,11,12,13,14]showed that Sienna+ is non-inferior to standard mapping techniques for sentinel node detection. There was no difference in detection rate per patient (fixed odds ratio (OR) 1.10; 95% confidence interval (CI) 0.67-1.79; p = 0.71) between Sienna+ and the standard tracer technique.…”
Section: Superparamagnetic Iron Oxidementioning
confidence: 99%
“…Dodatkowo ich czarnobrązowe zabarwienie pozwala na wzrokowe uwidocznienie węzła w polu operacyjnym. Badania kliniczne i z udziałem chorych w 12 krajach europejskich wykazały analogiczną wartość metody SentiMag® w porówna-niu z metodą standardową z użyciem gamma kamery i radioznacznika (Technetu (99mTc) samodzielnie lub w połączeniu Tc (99m) z niebieskim barwnikiem) [2,3,4,5,6]. Niewątpliwą zaletą SentiMag® jest możliwość jej stosowania przez chirurga w ośrodkach niemają-cych dostępu do radioizotopu, do tej pory pozbawionych możliwości wykonywania omawianej procedury.…”
Section: W St ę Punclassified