“…Massa and colleagues from the Geneva University Hospitals presented the SWISS IOL, a new minimally invasive technique for the scleral fixation of intraocular lenses (IOLs) in eyes without capsular support [ 6 ]. The postoperative spherical equivalent refraction ranged between −0.75 and −2.25, and no perioperative or postoperative complications were recorded while all IOLs were well centered postoperatively without any dislocation or tilt.…”