The temperature measurement of hydrogen flame based on CCD and IR images
Jianan Yin,
Changqing Dong,
Junjiao Zhang
et al.
Abstract:This study explored the relationship between the RGB color space and the temperature of hydrogen flames with thermal reflection principles. The prediction model based on CCD and infrared (IR) image were compared. The model based on RGB difference as inputs for CCD image showed an average relative error of 9.8314%. The model based on infrared image RGB values showed an average relative error of 6.6652%.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.