2013
DOI: 10.1016/j.jpowsour.2012.10.087
|View full text |Cite
|
Sign up to set email alerts
|

The testing of batteries linked to supercapacitors with electrochemical impedance spectroscopy: A comparison between Li-ion and valve regulated lead acid batteries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(14 citation statements)
references
References 12 publications
0
14
0
Order By: Relevance
“…By analyzing the EIS spectra, the equivalent series resistance (ESR, R s ) of the electrode, which includes inherent resistance of electrode materials, bulk resistance of the electrolyte and the contact resistance of the electrode/ electrolyte interface, can be calculated by the intercept of the spectra on the real axis. Moreover, the charge transfer resistance (R ct ) oringinated from diffusion of electrons can be deduced from the diameter of the semicircle in high frequency reigon [26]. The EIS of nanocomposites prepared in two processes by mass ratios from 8: 1: 1 to 6: 2: 2 are compared in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…By analyzing the EIS spectra, the equivalent series resistance (ESR, R s ) of the electrode, which includes inherent resistance of electrode materials, bulk resistance of the electrolyte and the contact resistance of the electrode/ electrolyte interface, can be calculated by the intercept of the spectra on the real axis. Moreover, the charge transfer resistance (R ct ) oringinated from diffusion of electrons can be deduced from the diameter of the semicircle in high frequency reigon [26]. The EIS of nanocomposites prepared in two processes by mass ratios from 8: 1: 1 to 6: 2: 2 are compared in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The present method based on an impedance spectroscopy of the internal battery impedance for selected frequency points. The cell internal impedance spectroscopy is currently used worldwide in many science centers as a research technique for electrochemical cells (Frank et al, 2015;Depernet et al, 2012;Huang et al, 2015;Yokoshima et al, 2015;Ferg et al, 2013;Kindermann et al, 2015) and fuel cells (Lepage et al, 2012). However, this method is so far extremely rarely used for electrochemical battery in industrial applications.…”
Section: Introductionmentioning
confidence: 99%
“…Due to their economic and technological importance, the electrochemical system of lead-acid batteries has been the subject of several researches, scientific studies and technical assessments (PITATOWICZ et al 2015;FERG et al 2013;…”
Section: Introductionmentioning
confidence: 99%