2013
DOI: 10.1088/1748-0221/8/01/t01003
|View full text |Cite
|
Sign up to set email alerts
|

The trigger and timing system of the Double Chooz experiment

Abstract: Modern precision neutrino experiments like Double Chooz require a highly efficient trigger system in order to reduce systematic uncertainties. The trigger and timing system of the Double Chooz experiment was designed according to this goal. The Double Chooz trigger system is driven by the basic idea of triggering on multiple thresholds according to the total visible energy and additionally triggering on the number of active photomultiplier tubes (PMTs) in the detector. To do so, the trigger system continuously… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
16
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(16 citation statements)
references
References 19 publications
0
16
0
Order By: Relevance
“…The detector is surrounded by 15 cm of demagnetized steel to suppress external γ-rays. The main detector is covered by an outer veto system (not used in this analysis).The readout is triggered by custom energy sum electronics [33][34][35]. The ID PMTs are separated into two groups of 195 PMTs uniformly distributed throughout the volume and the PMT signals in each group are summed.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The detector is surrounded by 15 cm of demagnetized steel to suppress external γ-rays. The main detector is covered by an outer veto system (not used in this analysis).The readout is triggered by custom energy sum electronics [33][34][35]. The ID PMTs are separated into two groups of 195 PMTs uniformly distributed throughout the volume and the PMT signals in each group are summed.…”
mentioning
confidence: 99%
“…The readout is triggered by custom energy sum electronics [33][34][35]. The ID PMTs are separated into two groups of 195 PMTs uniformly distributed throughout the volume and the PMT signals in each group are summed.…”
mentioning
confidence: 99%
“…A summed signal that is created in the FEE is used for the trigger [68]. The amplitude is roughly proportional to the charge collected at the PMT anodes.…”
Section: Outer Muon Vetomentioning
confidence: 99%
“…PPO and bis-MSB were added as fluor and wavelength-shifter, respectively. Three remotely operated calibration units mounted on top of each steel vessel allow for the deployment of an LED, a 68 Ge source, and a combined neutron/gamma source of 241 Am-13 C and 60 Co among three vertical axes. In each antineutrino detector, 192 20-cm PMTs along the side wall of the steel vessel detect the photons from interactions in the scintillators.…”
Section: Layout Of the Antineutrino Detectorsmentioning
confidence: 99%
See 1 more Smart Citation