“…Elevations may be indicative of a variety of non-coronary disorders such as sepsis, renal failure, pulmonary embolism, hypotension, pericarditis and congestive heart failure 3. Also of note, false-positive results may be caused by antianimal ‘heterophile’ antibodies, antitroponin antibodies, fibrin clots,4 5 microparticles, analyser malfunction or rheumatoid factors 5. It is estimated that heterophilic antibodies interfere with assays in 2.0% of cases 6…”