Photons Plus Ultrasound: Imaging and Sensing 2019 2019
DOI: 10.1117/12.2507448
|View full text |Cite
|
Sign up to set email alerts
|

The Twente Photoacoustic Mammoscope 2: 3D vascular network visualization

Abstract: We present the Twente Photoacoustic Mammoscope 2 (PAM 2) based on a 3D tomographic geometry. A functional optical contrast map of breast vascularization can be obtained in a noninvasive, radiation-free and painless manner. A woman lies prone on a bed with one breast pendant in an imaging tank with water, where 12 curved ultrasound arrays are mounted. Each array extends from chest wall towards the nipple following the contour of the pendant breast, and carries 32 detector elements. The detectors' center frequen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4
2

Relationship

5
1

Authors

Journals

citations
Cited by 6 publications
(13 citation statements)
references
References 23 publications
(21 reference statements)
0
13
0
Order By: Relevance
“…10(a)). The PA imaging depth in the phantom was found to be 27 mm, while the imaging depth in healthy volunteer measurements was logged to be 20-22 mm [8,79]. The breast tissue properties of these specific volunteers are unknown, which makes it impossible to make a fair comparison.…”
Section: Discussion and Outlookmentioning
confidence: 99%
See 2 more Smart Citations
“…10(a)). The PA imaging depth in the phantom was found to be 27 mm, while the imaging depth in healthy volunteer measurements was logged to be 20-22 mm [8,79]. The breast tissue properties of these specific volunteers are unknown, which makes it impossible to make a fair comparison.…”
Section: Discussion and Outlookmentioning
confidence: 99%
“…The healthy volunteer is a 29 year-old woman, having a light skin tone. Schoustra et al logged an imaging depth of 20 mm for this healthy volunteer measurement [79] and a depth of 22 mm for a measurement on a 25 year old healthy volunteer [8]. These values were obtained by tracing one of the blood vessels up to the deepest depth where it was still visible.…”
Section: Imaging Performancementioning
confidence: 99%
See 1 more Smart Citation
“…Additionally, it was imaged with the Twente Photoacoustic Mammoscope 2 (PAM2). 19,20 The phantom was illuminated with 755 nm pulses fired by an Alexandrite laser with a duration of 60 ns. Twelve arc-shaped ultrasound detector arms, each containing 32 elements with a 1 MHz center frequency, rotated 60 degrees around the phantom in 45 steps.…”
Section: Imagingmentioning
confidence: 99%
“…Recently, we described our three-dimensional (3D) tomographic system for photoacoustic breast imaging: PAM 2 [ 25 , 26 ]. In this work, the first human subject measurements with the system were reported, where the breast was imaged while freely pendant inside the imaging tank filled with water.…”
Section: Introductionmentioning
confidence: 99%