The Use of Ethylene Oxide for Sterilization of Mechanical Ventilators

Abstract: A method of sterilizing intermittent positive pressure ventilators is described, using 10 per cent ethylene oxide in 90 per cent carbon dioxide. This method can be used for any type of machine available, and several different methods are described to suit the variety of ventilators. Essentially, ethylene oxide is introduced into a large bag enclosing the ventilator, which is allowed to cycle for up to 24 hours. The bag is made of Terykne, proofed with Neoprene to prevent diffusion and dilution of the gas. A si… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

1965
1965
1980
1980

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(2 citation statements)
references
References 3 publications
0
2
0
Order By: Relevance
“…Prior to their use, the ventilators were connected to an M.R.I. apparatus (Mallet, 10 Rue de Milan, Paris), and sterilized with ethylene oxide with COZ, (BISHOP et al 1964). The connecting tube5 were disinfected by immersion in a hydroalcoholic solution of chlorhexidine (Hibitane@), for 12 h. All bacteriological controls after sterilization and disinfection were negative.…”
Section: Ventilatorsmentioning
confidence: 99%
“…Prior to their use, the ventilators were connected to an M.R.I. apparatus (Mallet, 10 Rue de Milan, Paris), and sterilized with ethylene oxide with COZ, (BISHOP et al 1964). The connecting tube5 were disinfected by immersion in a hydroalcoholic solution of chlorhexidine (Hibitane@), for 12 h. All bacteriological controls after sterilization and disinfection were negative.…”
Section: Ventilatorsmentioning
confidence: 99%
“…The potential hazard of contaminated inhalation therapy equipment has now been clearly documented both by systematic studies (13) and by reports of nosocomial pulmonary infection related to bacterial contamination of nebulizers and other apparatus used for respiratory care in the hospital (7,10,14). A number of methods for periodic disinfection of this equipment have been described (1,5,6,9,12,15,16), and there is evidence that programs which reduce the contamination of this equipment decrease the frequency of a type of pneumonia associated with gram-negative bacteria (12). Bacteriological sampling plays an important role in establishing the effectiveness of programs designed to decrease the infection hazard associated with inhalation therapy.…”
mentioning
confidence: 99%