1982
DOI: 10.1002/jcp.1041120221
|View full text |Cite
|
Sign up to set email alerts
|

The use of fluorescent dyes to measure membrane potentials: A critique

Abstract: Under controlled conditions, fluorescent cyanine dyes can be used to measure membrane potentials of cell suspensions. Similar changes in membrane potential can be followed both with fluorescent dyes and electrophysiological probes in response to changes in the ion composition of the medium. Recent reports that attempt to abrogate the use of the cyanine dyes in measurements of the membrane potential are misleading.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
18
0

Year Published

1982
1982
1989
1989

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 27 publications
1
18
0
Order By: Relevance
“…Johnstone et al, 1982;Smith 1982). Estimates of V,,+ based on indirect methods generally give values greater than those obtained by direct electrophysiological techniques (Laris et al, 1976, Philo & Eddy, 1978Smith & Robinson, 1981b).…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…Johnstone et al, 1982;Smith 1982). Estimates of V,,+ based on indirect methods generally give values greater than those obtained by direct electrophysiological techniques (Laris et al, 1976, Philo & Eddy, 1978Smith & Robinson, 1981b).…”
Section: Discussionmentioning
confidence: 98%
“…In general, two different methods have been applied to estimate Vm: direct electrophysiological measurements utilizing intracellular microelectrodes, and indirect determinations utilizing passively distributed ions. The estimates achieved by these approaches are not always in good agreement (@ Johnstone, Laris & Eddy, 1982;Smith, 1982). Typically, direct measurements by microelectrodes give vahles in the range -20 to -30 mV (Lassen et al, 1971;Smith & Vernon, 1979;Smith & Robinson, 1981b;Dawson & Smith, 1986), while indirect estimates are significantly more elevated (-40 to -60 mV; Laris et al, 1976;Hoffmann & Lambert, 1983;Valdeolmillos, GarciaSancho & Herreros, 1986).…”
Section: Introductionmentioning
confidence: 95%
“…Several side effects of the dye have, however, been under discussion (for example, see Johnstone et al, 1982;Smith, 1982). The major points investigated have been, the effect of the dye-induced inhibition of the respiration, and an eventual change in the K + permeability caused by the dye.…”
Section: Evaluation Of the Fluorescense Methods And The Thiocyanate DImentioning
confidence: 99%
“…Where most of the microelectrode measurements may have given erroneously low values for the membrane potentials due to leakage caused by the microelectrode impalements, the results obtained with the dyes have, on the other hand, been questioned for the possible effects of the dye on the ionic conductances as well as errors introduced by the calibration of the dyes using the "valinomycin null-point" method (see Johnstone, Laris & Eddy, 1982;Smith, 1982). In the present report, the fluorescence of the dye DiOC3-(5) is calibrated in Na+-free media using gramicidin instead of valinomycin to increase the cation permeability of the cell membrane.…”
Section: Introductionmentioning
confidence: 99%
“…I feel, therefore, that instead of putting the problems into perspective, the preceding paper (Johnstone et al, 1982) is more apt to obscure them in a rosecolored mist.…”
mentioning
confidence: 88%