Annual Review of Hydrocephalus 1989
DOI: 10.1007/978-3-662-11149-9_55
|View full text |Cite
|
Sign up to set email alerts
|

The Use of Shunting Devices for Cerebrospinal Fluid in Canada

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
3
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 0 publications
2
3
0
Order By: Relevance
“…The results of this study support the previous arguments of ensuring optimal ventricular catheter tip positioning. We propose that the success of shunt patency in these optimal locations is due to the higher likelihood, anatomically, of the catheter tip being completely surrounded by CSF.…”
Section: Discussionsupporting
confidence: 89%
See 3 more Smart Citations
“…The results of this study support the previous arguments of ensuring optimal ventricular catheter tip positioning. We propose that the success of shunt patency in these optimal locations is due to the higher likelihood, anatomically, of the catheter tip being completely surrounded by CSF.…”
Section: Discussionsupporting
confidence: 89%
“…This may be due to the anatomy of the body and trigone of the lateral ventricles in having smaller dimensions than the frontal horns and also containing choroid plexus, which has been implicated in causing shunt blockage. The suggestions for ‘optimal’ tip location to be anterior to the foramen of Monro in the ipsilateral frontal horn of the lateral ventricle are supported by the findings of this study. All catheter tips in this optimal position that were completely surrounded by CSF were found to be patent on infusion test; 40/40 (100%) of optimally positioned catheters were completely surrounded by CSF, but only 52/266 (21%) of suboptimally positioned were completely surrounded by CSF.…”
Section: Discussionsupporting
confidence: 76%
See 2 more Smart Citations
“…Rather, flanged shunt catheters proved problematic when a shunt revision was required, due to the adhesions that form around the flanges, leading to an increased risk of choroid plexus avulsion when removed 3 . By the mid-1980s, the use of flanged catheters was being discouraged 4 . Flanged catheters are now used infrequently, but were being sold in Canada as recently as 2018 (personal communication with Medtronic sales and marketing representatives).…”
mentioning
confidence: 99%