2013
DOI: 10.1309/ajcpduzvrn5vy9wz
|View full text |Cite
|
Sign up to set email alerts
|

The Usefulness of Blast Flags on the Sysmex XE-5000 Is Questionable

Abstract: Hematology analyzers generate suspect flags that involve microscopic reviews to confirm the presence of pathologic cells. This study investigated the reliability of the blast flag in a side-by-side evaluation of 3 Sysmex XE-5000 instruments (Sysmex, Kobe, Japan). The repeatability of the Q values reported by each instrument for 10 replicates of the same blood samples was low (intraclass correlation coefficient [ICC] values, 0.62-0.74). The reproducibility of the Q values obtained by analyzing 408 samples on al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
16
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(18 citation statements)
references
References 11 publications
2
16
0
Order By: Relevance
“…Compared to the sensitivity results published in some papers for Sysmex XN, XE‐5000, and XE‐2100 analyzers , we obtained a relatively lower result. For Sysmex XE‐5000 analyzer, our results were closer to the ones found in other papers . The sensitivity results in our group of patients were similar to some published results with other analyzers as Abbott Cell‐Dyn Sapphire, ADVIA 2120, and Beckman Coulter DxH 800 and LH 750 .…”
Section: Discussionsupporting
confidence: 91%
“…Compared to the sensitivity results published in some papers for Sysmex XN, XE‐5000, and XE‐2100 analyzers , we obtained a relatively lower result. For Sysmex XE‐5000 analyzer, our results were closer to the ones found in other papers . The sensitivity results in our group of patients were similar to some published results with other analyzers as Abbott Cell‐Dyn Sapphire, ADVIA 2120, and Beckman Coulter DxH 800 and LH 750 .…”
Section: Discussionsupporting
confidence: 91%
“…The LUC in contrast to flags has controls, and increases the detection rate for acute leukemia in adults. Others have questioned the usefulness of the blast flags on the Sysmex XE-5000 because of the low repeatability in repeated measurements from the same sample in the same instrument, lack of agreement among harmonized instruments, and the inability to predict the presence and absence of blasts on peripheral smear review [18].…”
Section: Discussionmentioning
confidence: 99%
“…Despite the continuous improvement of the hematology analyzers, the flags are subject to ambiguities that require further examination. Several previous studies have evaluated the flagging performance of modern hematology instruments by comparing the data with the manual blood smear examination . Microscopic counting and characterization of blood cells have been considered as the reference method despite the fact that the method is cumbersome, time‐consuming, and also affected by inter‐observer differences.…”
Section: Introductionmentioning
confidence: 99%