2017
DOI: 10.1002/jcu.22505
|View full text |Cite
|
Sign up to set email alerts
|

The utility of on‐site ultrasound screening in population at high risk for deep venous thrombosis in temporary housing after the great East Japan Earthquake

Abstract: Ultrasonography is efficient for screening at-risk populations in challenging settings. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:566-574, 2017.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
30
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(31 citation statements)
references
References 31 publications
0
30
0
1
Order By: Relevance
“…When subjects answered in the questionnaire that the time spent walking was reduced in comparison with before the disaster, they were classified as having reduced walking hours. The ultrasonography was performed by several medical technologists, each with more than five years of experience [5,6]. To improve uniformity, the evaluation criteria were discussed prior to the screening [5,6].…”
Section: Examination Itemsmentioning
confidence: 99%
See 3 more Smart Citations
“…When subjects answered in the questionnaire that the time spent walking was reduced in comparison with before the disaster, they were classified as having reduced walking hours. The ultrasonography was performed by several medical technologists, each with more than five years of experience [5,6]. To improve uniformity, the evaluation criteria were discussed prior to the screening [5,6].…”
Section: Examination Itemsmentioning
confidence: 99%
“…The ultrasonography was performed by several medical technologists, each with more than five years of experience [5,6]. To improve uniformity, the evaluation criteria were discussed prior to the screening [5,6]. Screening was undertaken using portable ultrasound machines (LOGIQe, GE Healthcare with a 3.3-10.0 MHz linear probe; Noblus, Hitachi Medical Corporation with a 5-18 MHz linear probe; CX50, Philips Japan, Ltd., with a 3-12 MHz linear probe; Viamo, Canon Medical Systems Corporation with a 6.2-11.0 MHz linear probe; NanoMaxx, SonoSite Inc., with a 6-13 MHz linear probe).…”
Section: Examination Itemsmentioning
confidence: 99%
See 2 more Smart Citations
“…After the Mid-Niigata Prefecture Earthquake in 2004 [1], it is estimated that tens of thousands of people spent several nights in automobiles. Within the confines of an automobile, people are forced to maintain the same body posture for an extended period of time, and with limited availability of water and voluntary restriction of fluid intake due to the difficulty of finding latrines, several cases of economy class syndrome were reported [1,2]. In order to reduce such stress and maintain the health of refugees, it is necessary to have emergency shelters that can be transported to the disaster site immediately following an event, which are easy enough for anyone to set up, ensure privacy for each family unit, and guarantee a certain level of comfort for up to several months.…”
Section: Introductionmentioning
confidence: 99%