2016
DOI: 10.1107/s1600577516005816
|View full text |Cite
|
Sign up to set email alerts
|

The vacuum ultraviolet beamline/endstations at NSRL dedicated to combustion research

Abstract: An undulator-based vacuum ultraviolet (VUV) beamline (BL03U), intended for combustion chemistry studies, has been constructed at the National Synchrotron Radiation Laboratory (NSRL) in Hefei, China. The beamline is connected to the newly upgraded Hefei Light Source (HLS II), and could deliver photons in the 5-21 eV range, with a photon flux of 10(13) photons s(-1) at 10 eV when the beam current is 300 mA. The monochromator of the beamline is equipped with two gratings (200 lines mm(-1) and 400 lines mm(-1)) an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
97
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 169 publications
(97 citation statements)
references
References 49 publications
0
97
0
Order By: Relevance
“…The qualification was accomplished by scanning the photoionization efficiency (PIE) spectrum of a designated mass peak . The quantification was performed according to the ion signal intensities and photoionization cross‐sections of species . To realize the accurate quantification, the flow rate of MeOH vapour was calculated carefully by controlling two mass flow controllers (MFCs), not simply by the flow rate difference between the MFCs.…”
Section: Methodsmentioning
confidence: 99%
“…The qualification was accomplished by scanning the photoionization efficiency (PIE) spectrum of a designated mass peak . The quantification was performed according to the ion signal intensities and photoionization cross‐sections of species . To realize the accurate quantification, the flow rate of MeOH vapour was calculated carefully by controlling two mass flow controllers (MFCs), not simply by the flow rate difference between the MFCs.…”
Section: Methodsmentioning
confidence: 99%
“…Similar operating conditions were used, but replacing He by Ar that served as a reference in the SVUV-PI-MBMS data evaluation. The apparatus has been described elsewhere [20]. Gas samples were extracted from the JSR by a quartz sampling cone.…”
Section: Jsr-svuv-pi-mbms Experimentsmentioning
confidence: 99%
“…to confirm important trends obtained in the JSR-GC experiments, (ii) to detect species that cannot be measured by GC such as hydroperoxide species, and (iii) to assist in the identification of important LT intermediates. A detailed description of the apparatus is available in [18,19].…”
Section: Combination Of Jsr and Svuv-pi-mbms (Hefei)mentioning
confidence: 99%