1976
DOI: 10.21236/adb013164
|View full text |Cite
|
Sign up to set email alerts
|

The Vapor Pressure of Chemical Agents: GD, VX, EA 2223, EA 3547, EA 3580, EA 5365, and EA 5533

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…Savage and Fielder's Knudsen sample was reported to be 89 % pure; however, it is likely that the material was actually of higher purity during data collection due to outgassing of higher-volatility impurities in the process of measuring the data. 11 The DTA data reported earlier by Belkin and Brown vary by an average of 14.2 % from the calculated values, although as indicated in Table 5, the agreement between the higher calculated and observed values is much better than the lower values of that data set. 12 Figure 7 shows a comparison of the error anticipated for RVX superimposed by the DTA data measured by the authors as part of the current work.…”
Section: ■ Discussionmentioning
confidence: 55%
See 4 more Smart Citations
“…Savage and Fielder's Knudsen sample was reported to be 89 % pure; however, it is likely that the material was actually of higher purity during data collection due to outgassing of higher-volatility impurities in the process of measuring the data. 11 The DTA data reported earlier by Belkin and Brown vary by an average of 14.2 % from the calculated values, although as indicated in Table 5, the agreement between the higher calculated and observed values is much better than the lower values of that data set. 12 Figure 7 shows a comparison of the error anticipated for RVX superimposed by the DTA data measured by the authors as part of the current work.…”
Section: ■ Discussionmentioning
confidence: 55%
“…Coulter et al determined the flash point of VX to be 432 K using an open cup method. 2 Table 5 lists the vapor pressure data measured for VX reported previously by the current authors in an in-house technical report using the vapor saturation method, 15 by Savage and Fielder using Knudsen effusion, 11 and by Belkin and Brown using DTA. 12 It should be noted that the values contained in ref 12 are correlated to the experimental data as recorded in Belkin's laboratory notebook.…”
Section: ■ Resultsmentioning
confidence: 99%
See 3 more Smart Citations