The Variable Ellipsoid Modeling Technique as a Verification Method for the Treatment Planning System of Gamma Knife Radiosurgery

Abstract: Objective : The secondary verification of Leksell Gamma Knife treatment planning system (LGP) (which is the primary verification system) is extremely important in order to minimize the risk of treatment errors. Although prior methods have been developed to verify maximum dose and treatment time, none have studied maximum dose coordinates and treatment volume. Methods : We simulated the skull shape as an ellipsoid with its center at the junction between the mammillary bodies and the brain stem. The radiation de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…Some institutions have developed in‐house computer programs to verify the treatment shot times from the planning system for a prescribed dose 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 . These programs usually perform a point‐dose calculation based on tissue–air ratio (TAR) lookup table for narrow 60 Co beams (12) and an algorithm for patient skull geometry reconstruction 13 , 14 , 15 .…”
Section: Introductionmentioning
confidence: 99%
“…Some institutions have developed in‐house computer programs to verify the treatment shot times from the planning system for a prescribed dose 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 . These programs usually perform a point‐dose calculation based on tissue–air ratio (TAR) lookup table for narrow 60 Co beams (12) and an algorithm for patient skull geometry reconstruction 13 , 14 , 15 .…”
Section: Introductionmentioning
confidence: 99%
“…However, these studies did not addressed the calculation of the radiation depth for each gamma ray. We have developed a verification program called VEMT, a simulation program written in Java, to address this problem for the GK model C 6) .…”
Section: Discussionmentioning
confidence: 99%
“…When a method is created, it would be far advantageous to obtain an algorithm with known formalism with secured agreement rate with LGP. In this regard, previous reports on verification methods are uniformly deficient due to a lack of statistical analysis9,11,13,14). Additionally, results of these studies were compared only in under certain conditions for limited parameters although many different LGP parameters are instantly available in clinical settings.…”
Section: Discussionmentioning
confidence: 99%
“…The modified variable ellipsoid modeling technique (MVEMT) was used as a verification method for our study9). For this, the patient's skull is viewed as an ellipsoid with the center at the mammillary body.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation