2022
DOI: 10.5371/hp.2022.34.2.115
|View full text |Cite
|
Sign up to set email alerts
|

The Wear Rate and Survivorship in Total Hip Arthroplasty Using a Third-generation Ceramic Head on a Conventional Polyethylene Liner: A Minimum of 15-year Follow-up

Abstract: Purpose The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional ultra-high molecular weight polyethylene liner. Materials and Methods A total of 160 hips (147 patients with a mean age of 55.9 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003 were reviewed retrospectively. Evaluation of the wear rate for 5… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 32 publications
0
7
0
Order By: Relevance
“…Digital imaging software (PolyWare; Draftware Developers Inc., Vevay, IN, USA) was used to measure anteversion and inclination of the acetabular cup 14,15 . The software also calculated the linear and volumetric wear rates.…”
Section: Methodsmentioning
confidence: 99%
“…Digital imaging software (PolyWare; Draftware Developers Inc., Vevay, IN, USA) was used to measure anteversion and inclination of the acetabular cup 14,15 . The software also calculated the linear and volumetric wear rates.…”
Section: Methodsmentioning
confidence: 99%
“…Combinations including PE and ceramic or metal are called “hard-on-soft” (most commonly used) and those without PE “hard-on-hard”. The bearing surface is a significant factor in determining the longevity of THA, as worldwide concerns regarding expanding burden for revision procedures are emerging, secondary to loosening and osteolysis, depending on the type of bearing couples [ 52 ].…”
Section: Types Of Hamentioning
confidence: 99%
“…However, the optimal bearing surfaces are still under debate. PE liners are often used on the acetabular side, regardless of the artificial head [ 52 ]. MoM THA with large femoral head diameters have led to a high rate of adverse reactions to metal debris and pseudo-tumors, leading to an almost worldwide cessation of their use and reinforced surveillance [ 53 ].…”
Section: Types Of Hamentioning
confidence: 99%
See 2 more Smart Citations