Order By: Relevance
“…PMT signals exceeding a channel-specific threshold above the baseline, accepting on average 93% of SPE signals, are digitized at a rate of 10 8 samples=sec by the data acquisition (DAQ) system [27]. These signals are referred to as pulses.…”
Section: Signal Reconstruction and Simulationmentioning
confidence: 99%
See 2 more Smart Citations
“…PMT signals exceeding a channel-specific threshold above the baseline, accepting on average 93% of SPE signals, are digitized at a rate of 10 8 samples=sec by the data acquisition (DAQ) system [27]. These signals are referred to as pulses.…”
Section: Signal Reconstruction and Simulationmentioning
confidence: 99%
“…3. Compared to SR1, the S1 efficiency for SR0 is slightly smaller at the threshold due to a higher PMT noise level in the first third of SR0 dark matter data acquisition that could be reduced by installing low-pass filter boxes at the PMT high-voltage modules [27]. The S2 trigger efficiency of the offline event builder is determined by applying the trigger algorithm to simulated S2 waveforms that were generated homogeneously throughout the TPC.…”
Section: Signal Reconstruction and Simulationmentioning
confidence: 99%
See 1 more Smart Citation
“…This was based on the onsets for electroluminescence and charge multiplication in LXe at 412 +10 −133 kV/cm and 725 +48 −139 kV/cm, respectively [8] (see also [9,10]), while practical LXe-TPC cathodes made from stainless steel wires have been limited to surface fields of 40-65 kV/cm [11][12][13][14][15][16]. A detector with gold-plated stainless steel wires could not operate at the design field either [17]. A chamber with Monel wires, known for its resistance to corrosion, sustained 35 kV/cm on the gate grid [18].…”
Section: Introductionmentioning
confidence: 99%
“…The output of the amplifiers is sent to CAEN V1724 waveform digitizer modules to record the signals at a sampling rate of 100 MHz with a 2.25 V dynamic range, a 40 MHz input bandwidth, and 14-bit resolution. The data acquisition system is described in detail in [10].…”
Section: The Xenon1t Experimentsmentioning