2019
DOI: 10.20944/preprints201905.0047.v1
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

The Young Interferometer as Optical System for Variable Depolarizer Characterization

Abstract: In a depolarizing instrument, such as a broadband imaging spectrometer, the depolarizers are placed on the system for stabilization the optical signal. They are also used to reduce measurements offsets due to strong polarization dependence, which produce drastic deterioration of the signal to noise ratio. Dynamic depolarizer with a controllable degree of polarization is also required to study the effect of noise on quantum information. The article described a new instrument for characterization the variable de… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…The adequate tool for studying the dynamic effects of the spatial distribution of birefringence upon switching a VAN cell by an electric field was a modified Young’s interferometer proposed in our previous works [15,16,17]. This interferometer was constructed in free space with the possibility of controlling the fringe pattern in real time to study polarization dynamics and their fluctuations in the time domain.…”
Section: Calibration and Essential Parameters Of The Applied Intermentioning
confidence: 99%
See 3 more Smart Citations
“…The adequate tool for studying the dynamic effects of the spatial distribution of birefringence upon switching a VAN cell by an electric field was a modified Young’s interferometer proposed in our previous works [15,16,17]. This interferometer was constructed in free space with the possibility of controlling the fringe pattern in real time to study polarization dynamics and their fluctuations in the time domain.…”
Section: Calibration and Essential Parameters Of The Applied Intermentioning
confidence: 99%
“…Light source: He-Ne laser with λ = 633 nm; P—linear polarizer; SF—spatial filter; L 1 , L 2 —lenses, BS—beam splitter; M 1 , M 2 —mirrors; T 1 , T 2 —telescopes, VAN—vertically aligned nematic liquid crystal cell; PhD—photodetector, Gen—generator, HP—half-wave plate, QP—quarter-wave plate. Adapted from [16,17].…”
Section: Figurementioning
confidence: 99%
See 2 more Smart Citations