1996
DOI: 10.1021/ac951149+
|View full text |Cite
|
Sign up to set email alerts
|

Theory and Practice of Rapid Flow-Through Analysis Based on Optode Detection and Its Application to pH Measurement as a Model Case

Abstract: Rapid flow-through analysis (RFA) based on optode (optical chemical sensor) detection is proposed, and its performance is discussed using the RFA system equipped with a pH-sensitive optode as a model case. To demonstrate and understand the usefulness of the RFA system, long-lifetime pH-sensitive optodes were prepared using a hydrophilic poly(hydroxyethyl methacrylate) (poly-HEMA) membrane covalently immobilized with a dye containing an amino group such as Congo Red or Nile Blue. The response equation for the o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2004
2004
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(17 citation statements)
references
References 25 publications
0
17
0
Order By: Relevance
“…Therefore, the necessity to develop new pH sensors is vital to control pH conditions in various environments. Due to their low-cost of manufacturing and maintenance, pH sensors were developed and used for both, clinical and environmental analyses [54][55][56]. Nevertheless, fluorescent pH indicators offer higher selectivity and sensitivity than other classes [28].…”
Section: Ph-sensitive Study and Pk A Determination Of 8 In Aqueous Somentioning
confidence: 99%
“…Therefore, the necessity to develop new pH sensors is vital to control pH conditions in various environments. Due to their low-cost of manufacturing and maintenance, pH sensors were developed and used for both, clinical and environmental analyses [54][55][56]. Nevertheless, fluorescent pH indicators offer higher selectivity and sensitivity than other classes [28].…”
Section: Ph-sensitive Study and Pk A Determination Of 8 In Aqueous Somentioning
confidence: 99%
“…In several FIA systems based on optode detectors, the onechannel FIA system, in which a sample solution is introduced into a flow of a regeneration solution (RS), is used. [21][22][23][24][25][26][27][28] Here, the more standard two-channel FIA system is adopted. Figure 1 depicts the two-channel FIA system, which is made up of two syringe pumps (YSP-101, YMC, Kyoto, Japan), a sample injector, a homemade optode detector, a light source (a tungstenhalogen lamp, LS-1, Ocean Optics, USA), and a fiber-optic spectrophotometer (USB 4000, Ocean Optics, USA) connected to a personal computer (PC).…”
Section: Fia System For the Determination Of Asmentioning
confidence: 99%
“…In addition, many toxic organic solvents such as chloroform are often used in the methods. Considering the above, there is a need for a simpler method based on chemical sensors such as ion selective electrodes (ISEs), [9][10][11][12][13][14][15][16] optical sensors (optodes) [17][18][19][20][21][22][23][24][25][26][27][28] and fiber optic sensors 29,30 to measure ASs without the use of toxic organic solvents.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Specially, these kinds of sensors suggest many advantages over the traditional systems, because of they offer the capacity of operating in hostile and dangerous environments [1][2][3][4]. The study of these sensors is attractive since they allow us to perform in vivo analysis and in situ monitoring.…”
Section: Introductionmentioning
confidence: 99%