Thermal Deformation Analysis and Measurement of the Triple Grid for a 30cm Diameter Ion Thruster

Abstract: Critical ion thruster component that affects operation and service life is the grids assembly, and the hot gap variation of the grids directly determines the erosion process of the grids. In order to obtain the hot gap variation of the triple grid for a 30cm diameter ion thruster under 5kW work condition, finite element analysis is used to calculate the distribution of temperature and thermal deformation, then a deflection measurement experiment is carried out to verify the simulations. The results show that t… Show more