2016
DOI: 10.1016/j.enconman.2015.12.023
|View full text |Cite
|
Sign up to set email alerts
|

Thermal inertia of flat-plate solar collectors in different radiative regimes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
10
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(10 citation statements)
references
References 17 publications
0
10
0
Order By: Relevance
“…Early ground-based analyses have characterized single-site irradiance on time scales ranging from hours to months [20,21], while later studies have often been geared towards increasing temporal resolutions of, e.g., 300 s [22,23], 60 s [24][25][26][27], 20 s [12,28,29], 15 s [30][31][32][33][34][35][36][37][38][39][40], 10 s [10,13,41], 5 s [42,43], 1 s [14,[44][45][46][47][48][49][50][51][52][53][54][55][56][57][58][59][60][61], and occasionally even down to 0.1 s [62], 0.04 s [63], 0.01 s [16,…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Early ground-based analyses have characterized single-site irradiance on time scales ranging from hours to months [20,21], while later studies have often been geared towards increasing temporal resolutions of, e.g., 300 s [22,23], 60 s [24][25][26][27], 20 s [12,28,29], 15 s [30][31][32][33][34][35][36][37][38][39][40], 10 s [10,13,41], 5 s [42,43], 1 s [14,[44][45][46][47][48][49][50][51][52][53][54][55][56][57][58][59][60][61], and occasionally even down to 0.1 s [62], 0.04 s [63], 0.01 s [16,…”
Section: Introductionmentioning
confidence: 99%
“…the analysis of power spectra and non-linear characteristics of PV power and solar irradiance time series [17,18,44,47,54,55,60,[77][78][79][80][81][82], • the consideration of sunshine number and sunshine stability number to characterize the level and stability of the solar radiative regime [30][31][32][33][34][35][36][37][38][39][40], • the intercomparison of solar irradiance fluctuations and power generation variability of co-located PV plants [26,55,70,83] the estimation of spatial smoothing, including correlation structures of irradiance and PV power, as well as their increments [10,12,13,16,27,41,45,49,51,52,61,68,70,71,[102][103][104][105]…”
mentioning
confidence: 99%
“…The thermal efficiency was found to vary between 22% and 40%. Soriga and Badescu [5] highlighted that the thermal inertia of a solar air heater ranged between 0.4 to 0.7. Sun et al [6] presented a mathematical model for SACs by varying the mass flow rate from 0.02 to 0.05 kg/s and solar radiation between 100 and 1000W/m 2 .…”
Section: Introductionmentioning
confidence: 99%
“…One way to compensate the lower performance of the flat plate solar thermal collectors was proposed by Moss et al [16] through a prototype of an evacuated flat plate solar collector for which an efficiency higher than an evacuated tube by a factor of 1.32 was reported. Soriga and Badescu [17] developed a mathematical model to describe the dynamic behaviour of a flat plate solar collector based on which numerical simulations were performed to assess their thermal capacitance, the results showing a steady-state value of 5.37 kJ K −1 m −2 . Even in the case of evacuated tube solar thermal collectors improvements can be obtained as in the case of a novel evacuated tube solar collector having a parallel flow manifold header with a metal foam heat exchanger [18] presenting a performance enhancement factor ranging from 1.14 to 3.20.…”
Section: Introductionmentioning
confidence: 99%