Thermal Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 92 publications
0
5
0
Order By: Relevance
“…For each DSC measurement, a sample of mass between 10 and 15 mg was hermetically sealed in a standard DSC aluminum pan and measured in a He gas atmosphere, at a gas flow rate of 25 mL min −1 . The latent heat of fusion was determined from measurements performed at heating rates of 10 K/min and the melting temperature was determined from measurements at rates of 2 K/min, as recommended for high accuracy [41]. Typical uncertainties for this DSC system are ± 10 % for ∆ fus H and ± 1.5 • C for T mpt and at least 3 samples from each PCM were measured, and their values of ∆ fus H and T mpt were within these uncertainties.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For each DSC measurement, a sample of mass between 10 and 15 mg was hermetically sealed in a standard DSC aluminum pan and measured in a He gas atmosphere, at a gas flow rate of 25 mL min −1 . The latent heat of fusion was determined from measurements performed at heating rates of 10 K/min and the melting temperature was determined from measurements at rates of 2 K/min, as recommended for high accuracy [41]. Typical uncertainties for this DSC system are ± 10 % for ∆ fus H and ± 1.5 • C for T mpt and at least 3 samples from each PCM were measured, and their values of ∆ fus H and T mpt were within these uncertainties.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The melting temperature of a material from a DSC experiment corresponds to the onset of the melting peak, T onset [41]. However, due to the large number of components in the edible oils which broaden melting, the onset of melting was not well defined.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The instrument was calibrated using a fused quartz standard matched in length to the sample to within 5%. The standard uncertainty of the instrument in Δ / 0 was ±1%. , …”
Section: Experimental Sectionmentioning
confidence: 98%
“…The standard uncertainty of the instrument in Δ / 0 was ±1%. 17,63 Thermal Analysis. Differential scanning calorimetry (DSC) was used to delineate any phase transitions in ZrMgMo 3 O 12 with a 20.43 mg sample in an aluminum pan using a TA Instruments Q200 series differential scanning calorimeter equipped with a liquid N 2 cooling head.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…Following recommendations in Ref. 43, all calibrations and sample protocols were the same: same pan type, purge gas, flow rate and heating rate were used. These include using TA Instruments standard hermetic sample pans, nitrogen gas at a flow rate of 50 ml min −1 and heating rates of 10 C min −1 .…”
Section: Electrochemical Impedance Spectroscopy (Eismentioning
confidence: 99%