Thermal Performance Analysis of an Absorption Cooling System Based on Parabolic Trough Solar Collectors

Abstract: Solar radiation intensity significantly influences the cooling loads of building, and the two are correlated and accorded to a certain extent. This study proposes a double effect LiBr–H2O absorption cooling system based on the parabolic trough collector (PTC) of solar heat energy. Thermodynamic models including PTC and absorption chiller are constructed, and their accuracy is verified by comparing the simulation results and the experimental data. Subsequently, the impact of variable design parameters on the th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 30 publications
0
13
0
Order By: Relevance
“…In general, many of the studies and research papers focus on the performances of PTC-powered double-effect absorption system for space cooling. The studies prove that 50% of the cooling load could be covered [37], 69.47% of the solar energy utilization efficiency could be achieved [38] and 65% of the annual operating costs could be reduced [39]. The contribution to CO2 emission reduction of solar-assisted double-effect chillers is also pointed out compared to conventional cooling system [40].…”
Section: Introductionmentioning
confidence: 80%
“…In general, many of the studies and research papers focus on the performances of PTC-powered double-effect absorption system for space cooling. The studies prove that 50% of the cooling load could be covered [37], 69.47% of the solar energy utilization efficiency could be achieved [38] and 65% of the annual operating costs could be reduced [39]. The contribution to CO2 emission reduction of solar-assisted double-effect chillers is also pointed out compared to conventional cooling system [40].…”
Section: Introductionmentioning
confidence: 80%
“…The SACS can be driven by hot water with a relatively low temperature that can be provided by the common flat or evacuated tubes solar thermal collectors [6,9]. Concentrating solar collectors are also used in some solar cooling studies [5,13].…”
Section: Of 22mentioning
confidence: 99%
“…Since solar radiation is a major component of the cooling load, there is also a challenge to convert solar radiation into useful forms of energy [4]. Solar radiation directly influences the cooling load of buildings, thus the two are correlated at least to a certain extent [5].…”
Section: Introductionmentioning
confidence: 99%
“…Since solar radiation is a major component of the cooling load, there is also a challenge to convert the solar radiation into useful forms of energy [4]. Solar radiation directly influences the cooling loads of the building, thus the two are correlated at least to a certain extent [5].…”
Section: Introductionmentioning
confidence: 99%
“…The SACS can be driven by hot water with relatively low temperature that can be provided by common flat or evacuated tubes solar thermal collectors [6,9]. Concentrating solar collectors are also used in some solar cooling studies [5,13].…”
Section: Introductionmentioning
confidence: 99%