2016 International Seminar on Sensors, Instrumentation, Measurement and Metrology (ISSIMM) 2016
DOI: 10.1109/issimm.2016.7803729
|View full text |Cite
|
Sign up to set email alerts
|

Thermal resistance measurements of building envelope components of the minang traditional house using the heat flow method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…The thermal performance of structural elements and materials are continuously analyzed and improved to reduce heat losses and increase the efficiency of building projects [ 13 ]. The thermal transmittance value (U-value), which measures how well insulated a building element is, provides an accurate assessment.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The thermal performance of structural elements and materials are continuously analyzed and improved to reduce heat losses and increase the efficiency of building projects [ 13 ]. The thermal transmittance value (U-value), which measures how well insulated a building element is, provides an accurate assessment.…”
Section: Introductionmentioning
confidence: 99%
“…During the test, the interior side will preferably offer higher stability in temperature. The main drawbacks are, firstly, that the data obtained must meet the criteria of standards, then measurement duration can be very long due to low-temperature differences between both wall sides [ 13 , 38 ], and secondly, reported data must be corrected with information about heat storage and measuring conditions to improve the estimation accuracy [ 38 , 39 ]. Although the in-situ-based measurements are easy to obtain especially if a heat flux meter is used [ 40 ], the measurements should be analyzed by a person with experience in order to obtain reliable results [ 39 ], especially when the measurement is performed in a low heat-flux regime [ 40 ].…”
Section: Introductionmentioning
confidence: 99%
“…The thermal performance of building materials is an important factor that greatly affects a building's energy performance and efficiency, i.e., it is used for the energy auditing of new and existing buildings [1][2][3]. It describes how building materials respond to the ambient environment in the daily or seasonal cycle.…”
Section: Introductionmentioning
confidence: 99%
“…Assessing how much warmth is lost during outer and inside walls is a key prerequisite for building energy test systems and is essential for quality confirmation and successful management in strategy usage and building design, construction and renovation. Accurate techniques for investigation to calculate the thermal execution of an entire building envelope or a component are, along these lines, required [16]. The investigations that manage the thermal execution of explicit building segments, and not the building all in all, have their very own benefits [17].…”
Section: Introductionmentioning
confidence: 99%