Thermal Transmittance and the Embodied Energy of Timber Frame Lightweight Walls Insulated with Straw and Reed

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 1 publication
0
7
0
Order By: Relevance
“…Researchers around the globe have examined the potential of using reed as building thermal insulation [10,[17][18][19]. Some studies have looked at the thermal capabilities of boards containing reed as a component of bio-based materials [18], while others have focused on boards made entirely of natural reed [19].…”
Section: Reed As a Thermal Insulation Materialsmentioning
confidence: 99%
See 3 more Smart Citations
“…Researchers around the globe have examined the potential of using reed as building thermal insulation [10,[17][18][19]. Some studies have looked at the thermal capabilities of boards containing reed as a component of bio-based materials [18], while others have focused on boards made entirely of natural reed [19].…”
Section: Reed As a Thermal Insulation Materialsmentioning
confidence: 99%
“…Researchers around the globe have examined the potential of using reed as building thermal insulation [10,[17][18][19]. Some studies have looked at the thermal capabilities of boards containing reed as a component of bio-based materials [18], while others have focused on boards made entirely of natural reed [19]. Regardless of the form it takes, reed has been found to have a satisfactory thermal performance, with thermal conductivity values ranging from 0.045-0.056 W/m.K [5].…”
Section: Reed As a Thermal Insulation Materialsmentioning
confidence: 99%
See 2 more Smart Citations
“…One of the tested wall elements was constructed from 500 mm thick straw-bales and rendered with 40 mm clay plaster outside and inside. Calculated thermal transmittance of this test element was U = 0.182 W/(m²·K) [6], but the result from the office with straw bale walls located at Tammistu (in Tartu county) was U = 0.092 W/(m²·K ) [7]. Having compared our results to those obtained in Germany we were intrigued to continue this research, and the master thesis was written about constructing the sauna and performing measurements.…”
Section: Introductionmentioning