1983
DOI: 10.1021/ac00264a022
|View full text |Cite
|
Sign up to set email alerts
|

Thermionic detection in microcolumn liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
18
1

Year Published

1984
1984
1997
1997

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(19 citation statements)
references
References 35 publications
0
18
1
Order By: Relevance
“…Novotny and co-workers [191][192][193] introduced a flame-based thermionic detector (TID) as a detection technique in capillary LC, The microcolumn LC mobile phase is nebulized with a hydrogen/nitrogen mixture into a primary flame. The combustion products are combined with additional fuel gas and are transported into the secondary, analytical flame.…”
Section: Thermionic Detectionmentioning
confidence: 99%
“…Novotny and co-workers [191][192][193] introduced a flame-based thermionic detector (TID) as a detection technique in capillary LC, The microcolumn LC mobile phase is nebulized with a hydrogen/nitrogen mixture into a primary flame. The combustion products are combined with additional fuel gas and are transported into the secondary, analytical flame.…”
Section: Thermionic Detectionmentioning
confidence: 99%
“…Obviously, direct sampling procedures are rarely used to deliver a desired sample size to the microcolumn. The moving injection technique (47), using electrically activated injection valves, appears to he adequate (27) for reproducible sampling in packed capillary columns: however, split injectors and heart-cutting devices (35, 40,48) are currently needed for smaller microcolumns (e.g., open tubular columns).…”
Section: Miniaturized Hdtumentationmentioning
confidence: 99%
“…The helium-cadmium laser (used a phosphorus-sensitive flame photoat either 325 or 442 nm) and the argon metric detector for capillary LC. This ion laser are now most favored by the work was further extended, and a douresearch groups involved with this type ble-flame thermionic detector for both of detection; however, as new laser the phosphorus-and nitrogen-containsources become practical they should ing compounds was designed (75,76). also be considered.…”
Section: New Detection Opportunities and Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Othe r detectio n device s wit h lo w detecto r cel l disperio n volume s hav e recentl y bee n described . Thes e includ e electrochemica l detector s [222][223][224] , infrare d monitor s [225] , post-colum n reactio n detector s [226] , flam e ionizatio n detector s [227] , thermioni c detector s [228] , flam e photometri c detector s [229] , an d fluorescenc e detector s [204] . …”
mentioning
confidence: 99%