2015
DOI: 10.1016/j.ijhydene.2015.07.077
|View full text |Cite
|
Sign up to set email alerts
|

THERMO economic analysis OF PV and hydrogen gas turbine hybrid power plant of 100 MW power output

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2016
2016
2025
2025

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…The upward and downward system spinning reserve requirements are set as 10% of the total load at each period, and other parameters for units can be found in [24]. The carbon tax price, captured CO 2 transmission and storage price, and CO 2 capture price from atmosphere are set as 20$/ton [28], 5$/ton [4] and 200$/ton [36], respectively. Forecast values of electrical load, gas load and wind generation are shown in…”
Section: -Bus Power System and 7-node Natural Gas Systemmentioning
confidence: 99%
“…The upward and downward system spinning reserve requirements are set as 10% of the total load at each period, and other parameters for units can be found in [24]. The carbon tax price, captured CO 2 transmission and storage price, and CO 2 capture price from atmosphere are set as 20$/ton [28], 5$/ton [4] and 200$/ton [36], respectively. Forecast values of electrical load, gas load and wind generation are shown in…”
Section: -Bus Power System and 7-node Natural Gas Systemmentioning
confidence: 99%
“…EVs are considered as the model of aggregator for energy dispatching, 30 RMB/ton Capture carbon from atmosphere 500 RMB/ton and they are connected at bus 2 to provide flexibility for IEGS. Some prices adopted in the optimization is listed as Table 1, the carbon tax price, payment for delivering CO 2 and price for capturing CO 2 form atmosphere are set as 120 RMB/ton [42], 30 RMB/ton [43] and 500 RMB/ton [44], respectively. The compensation costs of DRP is set as 60 RMB/MW and the penalty cost for wind power deviation is considered as 350 RMB/MW.…”
Section: Figure 4 Structure Of Iegsmentioning
confidence: 99%
“…In their research, the grid-tied solar PV–fuel cell hybrid power system exhibited a good performance for the tested system architectures. Ebaid et al (2015) employed the H 2 gas turbine instead of the fuel cell system as the electricity generator. They analyzed the PV–H 2 gas turbine system to generate a baseload of 100 MW.…”
Section: Introductionmentioning
confidence: 99%