2015
DOI: 10.15866/iremos.v8i3.5918
|View full text |Cite
|
Sign up to set email alerts
|

Thermo-Mechanical Model of Multi-Span Overhead Transmission Lines Equipped with High-Temperature Low-Sag Conductors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
2
1

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 0 publications
0
10
0
Order By: Relevance
“…(4) determines the steady-state temperature  std ;  the thermal time constant  The CIGRE document reports calculation methods for  and τ, taking into account thermo-fluid dynamic considerations; the calculation, based on the equilibrium between heat entering in the conductor and heat dispersed to the environment, is iterative, since  itself depends on the steady-state conductor temperature. In previous papers of the same authors [19] [20], new thermal models have been proposed and discussed also for High Temperature Low Sag conductors [21] [22].…”
Section: Heating Curve and Margin Of Overloadingmentioning
confidence: 99%
See 1 more Smart Citation
“…(4) determines the steady-state temperature  std ;  the thermal time constant  The CIGRE document reports calculation methods for  and τ, taking into account thermo-fluid dynamic considerations; the calculation, based on the equilibrium between heat entering in the conductor and heat dispersed to the environment, is iterative, since  itself depends on the steady-state conductor temperature. In previous papers of the same authors [19] [20], new thermal models have been proposed and discussed also for High Temperature Low Sag conductors [21] [22].…”
Section: Heating Curve and Margin Of Overloadingmentioning
confidence: 99%
“…In previous papers of the same authors, the described thermo-mechanical model was applied to compare the steady state and the dynamic performance of conductors [23] [24], or to estimate the calculation errors induced by the simplified "ruling span" technique [19] [20].…”
Section: Case Studymentioning
confidence: 99%
“…In order to address both targets, Ensiel (in particular the University of Pisa) has developed in the last years a novel thermo-mechanical model of a multi-span transmission line, by combining the CIGRE thermal model of conductors [9] and an innovative description of mechanical interactions existing among all the spans placed between two dead-end towers of the line [11] [12]. The main features of the weather-based DTR tool developed within the OSMOSE project, already described and discussed in [22], can be summarized as follows:…”
Section: Weather-based Dtr Methodsmentioning
confidence: 99%
“…The tool has been widely validated in previous works and compared with the state-of-the-art procedures [11] [12][21] [26]. This model has been implemented on two 150-kV sub-transmission lines located in Southern Italy.…”
Section: Weather-based Dtr Methodsmentioning
confidence: 99%
See 1 more Smart Citation