2015
DOI: 10.1016/j.ijrefrig.2014.11.009
|View full text |Cite
|
Sign up to set email alerts
|

Thermodynamic performance assessment of carbon dioxide blends with low-global warming potential (GWP) working fluids for a heat pump water heater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
34
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 105 publications
(34 citation statements)
references
References 24 publications
0
34
0
Order By: Relevance
“…After an initial screening, nine refrigerants were selected as candidates (listed in Table ) . The selection is mainly based on suitable thermodynamic properties and environment friendly properties: appropriate critical temperature to ensure the cycle operating in subcritical state, as transcritical and supercritical cycles were not in the scope of this study. evaporation pressure higher than 0.1 MPa and condensation pressure lower than 2.5 MPa to make components work effectively and stably. preference to zero ozone depletion potential (ODP) then low global warming potential (GWP) (less than 300) or safety. …”
Section: Refrigerant Selectionmentioning
confidence: 99%
See 2 more Smart Citations
“…After an initial screening, nine refrigerants were selected as candidates (listed in Table ) . The selection is mainly based on suitable thermodynamic properties and environment friendly properties: appropriate critical temperature to ensure the cycle operating in subcritical state, as transcritical and supercritical cycles were not in the scope of this study. evaporation pressure higher than 0.1 MPa and condensation pressure lower than 2.5 MPa to make components work effectively and stably. preference to zero ozone depletion potential (ODP) then low global warming potential (GWP) (less than 300) or safety. …”
Section: Refrigerant Selectionmentioning
confidence: 99%
“…After an initial screening, nine refrigerants were selected as candidates (listed in Table 5). [27][28][29] The selection is mainly based on suitable thermodynamic properties and environment friendly properties:…”
Section: Parameters In Heat Pump Cyclementioning
confidence: 99%
See 1 more Smart Citation
“…However, the CO 2 in the transcritical cycle will have great throttling loss and irreversibility, which is because the operating pressure on the high-pressure side is between 8 and 12 MPa. 15 This shortcoming limits the widespread use of CO 2 systems. Although the transcritical cycle overcomes the limitation of the early subcritical cycle of refrigeration capacity affected by the environment, the COP of the system remains low.…”
Section: Introductionmentioning
confidence: 99%
“…Much effort has been devoted to the system performance evaluation [17][18][19][20] and many novel optimizing strategies have been proposed based on extensive theoretical analysis and experimental tests [13,21,22]. Some other studies examined the performance of the gas cooler [23][24][25].…”
Section: Introductionmentioning
confidence: 99%