1994
DOI: 10.1006/jcht.1994.1029
|View full text |Cite
|
Sign up to set email alerts
|

Thermodynamic properties of heptacyclotetradecane C14H16

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
27
1

Year Published

1995
1995
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 28 publications
(28 citation statements)
references
References 0 publications
0
27
1
Order By: Relevance
“…and the mole-fraction purities x determined by the fractional-melting method for the samples used in the study described. (4)(5)(6)(7) The liquid samples of masses 1.03013 g for methyl benzoate, 0.61200 g for methyl o-toluate, 0.61162 g for methyl m-toluate, and 1.03417 g for methyl p-toluate were loaded into stainless-steel containers, which were filled with a heat-exchange helium gas. Containers were sealed with an indium gasket.…”
Section: Methodsmentioning
confidence: 99%
“…and the mole-fraction purities x determined by the fractional-melting method for the samples used in the study described. (4)(5)(6)(7) The liquid samples of masses 1.03013 g for methyl benzoate, 0.61200 g for methyl o-toluate, 0.61162 g for methyl m-toluate, and 1.03417 g for methyl p-toluate were loaded into stainless-steel containers, which were filled with a heat-exchange helium gas. Containers were sealed with an indium gasket.…”
Section: Methodsmentioning
confidence: 99%
“…(3)(4)(5)(6) The liquid samples with masses of 0.90825 g for CHF, 0.51808 g for CHA, 0.88950 g for CHB, and 0.56140 g for CHV were loaded into stainless-steel containers, which were filled with helium gas for heat-exchange. Container sealing was made with an indium gasket.…”
Section: Methodsmentioning
confidence: 99%
“…A more detailed description of the calorimeter appears in an earlier publication. (1) The molar heat capacities C sat, m of samples at Tq300 K and the molar enthalpy of fusion D fus H°m were measured by the triple heat-bridge method, which is described in detail elsewhere. (3) The error of the C sat, m measurements, as established by using reference compounds, did not exceed 1.5·10 −2 ·C sat, m to 2·10 −2 ·C sat, m .…”
Section: Methodsmentioning
confidence: 99%
“…(19) A detailed description of the apparatus has appeared in an earlier publication. (1) An isoperibol calorimeter equipped with a static bomb and an isothermal water jacket was used for measurements of the energy of combustion. The internal volume of the bomb was 320.5 cm 3 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation