2005
DOI: 10.1016/j.jct.2004.11.007
|View full text |Cite
|
Sign up to set email alerts
|

Thermodynamics of binary mixtures of N-methyl-2-pyrrolidinone and ketone. Experimental results and modelling of the (solid+liquid) equilibrium and the (vapour+liquid) equilibrium. The modified UNIFAC (Do) model characterization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(17 citation statements)
references
References 40 publications
0
17
0
Order By: Relevance
“…The isothermal VLE data for an aqueous solution have been measured by an ebulliometric method proposed by Rogalski and Malanowski within the pressure range up to p = 85 kPa at a wide composition range. A detailed description of the experimental procedure was described earlier . The main part of the apparatus is a specially designed ebulliometer which is connected to the pressure stabilizing system comprising the isolated container with a volume of 50 dm 3 enabling the pressure to be kept constant within 0.1 kPa and to dampen the pressure fluctuations caused by the bumping of the liquid boiling in the ebulliometer or by the variation of the temperature of the surroundings.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The isothermal VLE data for an aqueous solution have been measured by an ebulliometric method proposed by Rogalski and Malanowski within the pressure range up to p = 85 kPa at a wide composition range. A detailed description of the experimental procedure was described earlier . The main part of the apparatus is a specially designed ebulliometer which is connected to the pressure stabilizing system comprising the isolated container with a volume of 50 dm 3 enabling the pressure to be kept constant within 0.1 kPa and to dampen the pressure fluctuations caused by the bumping of the liquid boiling in the ebulliometer or by the variation of the temperature of the surroundings.…”
Section: Methodsmentioning
confidence: 99%
“…A detailed description of the experimental procedure was described earlier. 45 The main part of the apparatus is a specially designed ebulliometer which is connected to the pressure stabilizing system comprising the isolated container with a volume of 50 dm 3 enabling the pressure to be kept constant within 0.1 kPa and to dampen the pressure fluctuations caused by the bumping of the liquid boiling in the ebulliometer or by the variation of the temperature of the surroundings. The equilibrium temperature was measured using a resistance thermometer (type P-550, Roth, Germany) with a precision of 0.01 K. The pressure was measured with a precision of 0.1 kPa by a tensiometric vacuum meter (type CL 300, ZEPWN, Poland).…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the activity coefficient (γ 1 ) of the component, in the liquid phase, can be calculated according to Eq. 2 [5,20,21].…”
Section: Application Of Semi-empirical Modelsmentioning
confidence: 99%
“…The isothermal VLE data for an aqueous solution have been measured by the ebulliometric method within the pressure range of up to p = 85 kPa in a wide composition range. The main part of the apparatus is a specially designed ebulliometer, 21 which is connected to the pressure-stabilizing system comprising the thermostated container with a volume of 50 dm 3 enabling the pressure to be kept constant within 0.1 kPa and dampen the pressure fluctuations caused by the bumping of the liquid boiling in the ebulliometer or by the variation of the temperature of the surroundings. The equilibrium temperature was measured with a resistance thermometer (type P-550, ROTH, Germany) with a precision of 0.01 K. The pressure was measured with a precision of 0.1 kPa using a tensiometric vacuum meter (type CL 300, ZEPWN, Poland).…”
Section: Introductionmentioning
confidence: 99%