Thermoeconomic optimization for a finned-tube evaporator configuration of a roof-top bus air-conditioning system

Abstract: This paper presents a methodology of a design optimization technique that can be useful in assessing the best configuration of a finned-tube evaporator, using a thermoeconomic approach. The assessment has been carried out on a direct expansion finned-tube evaporator of a vapor compression cycle for a roof-top bus air-conditioning (AC) system at a specified cooling capacity. The methodology has been conducted by studying the effect of some operational and geometrical design parameters for the evaporator on the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…The current literature contains limited information on the design of the refrigerant distribution pipework for air conditioning systems and its influence on system performance . For example, Rajat et al evaluated the pressure drops along the suction pipeline from each evaporator exit to the compressor of the refrigeration plant.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The current literature contains limited information on the design of the refrigerant distribution pipework for air conditioning systems and its influence on system performance . For example, Rajat et al evaluated the pressure drops along the suction pipeline from each evaporator exit to the compressor of the refrigeration plant.…”
Section: Introductionmentioning
confidence: 99%
“…Brown et al investigated the exergy losses due to heat transfer and pressure drop of the refrigerant flowing through the evaporator. Mansour et al used a thermodynamics approach in optimizing a direct expansion finned‐tube evaporator in a roof‐top bus air conditioning system. An optimum number of rows and outside tube diameters were found in this study.…”
Section: Introductionmentioning
confidence: 99%
“…In the field of exergoeconomic (thermoeconomic) analysis of cold storage system, a considerable work was conducted by Bakan et al [12]. Moreover, there are several works relating to thermoeconomic optimization of heat exchangers of conventional heat pumps with no consideration on overall system [13,14].…”
Section: Introductionmentioning
confidence: 99%