2022
DOI: 10.1016/j.egyr.2022.09.040
|View full text |Cite
|
Sign up to set email alerts
|

Thermogravimetric analysis-based proximate analysis of agro-byproducts and prediction of calorific value

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 31 publications
0
5
0
Order By: Relevance
“…Specifically, postreaction catalyst samples were taken from three exemplary high-conversion reactions, namely, (a) 4 h, 40 bar H 2 , 275 °C, (b) 36 h, 30 bar H 2 , 275 °C, and (c) 4× repeated runs of 4 h, 30 bar H 2 , 300 °C each. To deconvolute the release of carbonaceous coke from polymeric species, a TGA program was implemented based on methods applied to biomass fraction determination, including a temperature-programmed pyrolysis (TPP) stage to 600 °C followed by cooling in an inert atmosphere and temperature-programmed oxidation (TPO) to 650 °C after that. Polyethylene has been shown to pyrolyze under an inert atmosphere by 550 °C .…”
Section: Resultsmentioning
confidence: 99%
“…Specifically, postreaction catalyst samples were taken from three exemplary high-conversion reactions, namely, (a) 4 h, 40 bar H 2 , 275 °C, (b) 36 h, 30 bar H 2 , 275 °C, and (c) 4× repeated runs of 4 h, 30 bar H 2 , 300 °C each. To deconvolute the release of carbonaceous coke from polymeric species, a TGA program was implemented based on methods applied to biomass fraction determination, including a temperature-programmed pyrolysis (TPP) stage to 600 °C followed by cooling in an inert atmosphere and temperature-programmed oxidation (TPO) to 650 °C after that. Polyethylene has been shown to pyrolyze under an inert atmosphere by 550 °C .…”
Section: Resultsmentioning
confidence: 99%
“…Moisture (M) content was measured by oven-drying samples at 105 °C until a constant weight was obtained. Volatile matter (VM) was measured gravimetrically by heating samples in a closed crucible at 900 ± 25 °C [ 35 , 36 ]. Ash content was determined by heating the samples in an open crucible at 575 ± 25 °C for 5 h (NREL/TP-510-42622 method) [ 37 ].…”
Section: Methodsmentioning
confidence: 99%
“…Nonetheless, chromium did not have a negative effect on the net calorific value or the gross calorific value of the dry matter of maize straw. It also needs to be emphasized that the calorific value of the dry matter of maize straw (18.2 MJ kg −1 ) [94] and (18.5 MJ kg −1 ) [95] is higher than that of oilseed rape straw (15.3 MJ kg −1 ) [96] or barley straw (15.7 MJ kg −1 ) [97]. Calorific value of various biomass types is presented in Table 1.…”
Section: Yield Of Zea Mays In Soil Contaminated With Cr(vi) and Its E...mentioning
confidence: 99%