Thermogravimetry coupled to an atmospheric pressure photo ionization quadrupole mass spectrometry for the product control of pharmaceutical formulations and the analysis of plasticizers in polymers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 45 publications
0
7
0
Order By: Relevance
“…PDMS was used as sorption material for TFME and two commercial PDMS films were tested using our developed TG-APPI-qMS system [20]. One PDMS film was purchased from Goodfellow GmbH (manufacturer A, Hamburg, Germany) with a film thickness of 0.45 mm (± 10%).…”
Section: Thin-film Microextractionmentioning
confidence: 99%
See 1 more Smart Citation
“…PDMS was used as sorption material for TFME and two commercial PDMS films were tested using our developed TG-APPI-qMS system [20]. One PDMS film was purchased from Goodfellow GmbH (manufacturer A, Hamburg, Germany) with a film thickness of 0.45 mm (± 10%).…”
Section: Thin-film Microextractionmentioning
confidence: 99%
“…The atmospheric pressure interface lenses (AP1 and AP2) were set to 40 and 20 V, respectively. The scan range was set to 50-700 Da and the dwell time to 2000 ms. A detailed description of the instrumental coupling of the thermogravimetry and the atmospheric pressure photo ionization quadrupole mass spectrometer (TG-APPI-qMS) is described in the literature [20]. To verify the ionization of cyclic siloxanes with atmospheric pressure ionization (APPI), D4-D6 standards were analysed.…”
Section: Tg-appi-qmsmentioning
confidence: 99%
“…29,30 The second mass spectrometric hyphenation is composed of a thermobalance (TG 209, Netzsch Geraẗebau, Selb, Germany) coupled to a modified Bruker GC-APCI II source equipped with atmospheric pressure photoionization (APPI) by a Kr vacuum ultraviolet lamp (10/10.6 eV, 124/117 nm) as a soft ionization technique preserving the molecular pattern. 31 The temperature program of the thermobalance with a constant flow of 200 mL/min nitrogen was 2 min isothermal at 20 °C, ramp to 600 °C with 10 K/min, and hold for 10 min at 600 °C. The evolved mixture was sampled via a 300 °C interface and 280 °C transfer line (deactivated fused silica capillary, 0.53 mm inner diameter, 300 °C) into the ion source of the mass spectrometer.…”
Section: ■ Introductionmentioning
confidence: 99%
“…These photons are thus able to ionize all organic compounds with an ionization energy less than 10 eV. [12][13][14][15][16][17] Another irradiation technique is atmospheric pressure laser ionization (APLI) which utilizes a laser with approximately 5 eV photon energy instead of the VUV lamp in APPI. 18 Penning ionization is also sometimes involved in various ionization techniques, but ESI and APCI are the most important and most common ionization mechanisms of all commercially available ion sources in an atmospheric pressure environment.…”