1970
DOI: 10.1016/s0021-9673(00)86699-6
|View full text |Cite
|
Sign up to set email alerts
|

Thin-layer chromatography of polymers introductory lecture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

1972
1972
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…Then tubes were placed on a hot plate and stirred with medium speed at 37 °C. Aliquots of 10 mL were withdrawn at different time points (1,2,4,12,24,36, and 48 h) and replaced the same with an equal volume of fresh buffers. The released fluoxetine concentration was analyzed through a UV-vis spectrophotometer at a wavelength of 227 nm.…”
Section: In-vitro Drug Releasementioning
confidence: 99%
“…Then tubes were placed on a hot plate and stirred with medium speed at 37 °C. Aliquots of 10 mL were withdrawn at different time points (1,2,4,12,24,36, and 48 h) and replaced the same with an equal volume of fresh buffers. The released fluoxetine concentration was analyzed through a UV-vis spectrophotometer at a wavelength of 227 nm.…”
Section: In-vitro Drug Releasementioning
confidence: 99%
“…From these investigations occasional molec ular weight effects were noted (8). Recently efforts in three separate laboratories have been successful in determining the molecular weight distribution of a polymer sample by TLC techniques (9)(10)(11)(12). An explana tion of the facility and high resolving power observed has been sought through a number of continuing experiments (11)(12)(13)(14)(15)(16).…”
Section: Thin-layer Chromatography (Tlc) Is a Common Laboratory Technmentioning
confidence: 99%
“…Recently efforts in three separate laboratories have been successful in determining the molecular weight distribution of a polymer sample by TLC techniques (9-12). An explana tion of the facility and high resolving power observed has been sought through a number of continuing experiments (11)(12)(13)(14)(15)(16). The purpose of this report is to review the results of these studies and to comment on the fractionation mechanisms postulated.…”
mentioning
confidence: 98%
“…TLC does not necessitate any expensive instruments and can be practiced easily. Validity of TLC in polymer chemistry has already been verified by some researchers (6,7,8). Kieselgei H (E. Merk Typ 60; layer thickness, 0.4 ram).was used as a stationary phase.…”
mentioning
confidence: 91%