Abstract:Palladium (Pd) membranes for hydrogen separation were deposited on modified porous stainless steel (PSS) tubes using the electroless plating technique. This study explores the hydrogen permeance influenced by the effect of reducing the thickness of the Pd membrane using different sizes of Al 2 O 3 particles, 10 and 1 mm, to modify the pores on the PSS surface. The pore size on the surface of the PSS tubes modified with 10 mm Al 2 O 3 particles decreased from 10 $ 20 mm to less than 5 mm, while the surface of t… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.