2013
DOI: 10.1111/echo.12382
|View full text |Cite
|
Sign up to set email alerts
|

Three‐Dimensional Echocardiographic Evaluation of a Patient with Double‐Orifice Mitral Valve, Bicuspid Aortic Valve, and Coarctation of Aorta

Abstract: A 16-year-old male patient was diagnosed with bicuspid aortic valve and coarctation of aorta, and had a history of a subclavian patch plasty operation at 1 year of age. In addition, we detected double-orifice mitral valve (DOMV) at a routine evaluation and demonstrated by both two-dimensional and three-dimensional (3D) echocardiographic examinations. DOMV should be kept in mind in cases with left ventricular obstructive lesions and 3D echocardiography may provide a more detailed assessment of mitral valve and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…1). Since these initial publications, many reports have described the use of real-time 3D TEE for imaging MV pathology [14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39]. For example, in 2013, we published a study on the superiority of real-time 3D TEE over 2D TEE for measuring the gap and width of a MV prolapse and flail [22].…”
Section: Mitral Regurgitationmentioning
confidence: 99%
“…1). Since these initial publications, many reports have described the use of real-time 3D TEE for imaging MV pathology [14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39]. For example, in 2013, we published a study on the superiority of real-time 3D TEE over 2D TEE for measuring the gap and width of a MV prolapse and flail [22].…”
Section: Mitral Regurgitationmentioning
confidence: 99%
“…The two-dimensional echocardiography (2DE) is the most common and important method for detecting congenital heart valvular disease [ 13 ]. Meanwhile, the role of real-time three-dimensional echocardiography (RT-3DE) in the diagnosis and evaluation of congenital heart diseases has been receiving more attention due to its ability to show the overall spatial structure of the heart [ 14 ]. Several novel 3DE imaging technologies have been developed by Philips Medical System recently.…”
Section: Introductionmentioning
confidence: 99%