Three-Dimensional Electrode Displacement Elastography Using the Siemens C7F2 fourSight Four-Dimensional Ultrasound Transducer

Abstract: Because ablation therapy alters the elastic modulus of tissues, emerging strain imaging methods may enable clinicians for the first time to have readily available, cost effective, real-time guidance to identify the location and boundaries of thermal lesions. Electrode displacement elastography is a method of strain imaging tailored specifically to ultrasound-guided electrode-based ablative therapies (eg. radiofrequency ablation). Here tissue deformation is achieved by applying minute perturbations to the uncon… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
42
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 53 publications
(42 citation statements)
references
References 31 publications
0
42
0
Order By: Relevance
“…These results also demonstrate the need for 3D strain imaging for complete tracking and measurement of the lesion volume. 29 Volume imaging of the ablation zone will reduce errors associated with area measurements. 29 The other limitations of this study include the use of a high transducer center frequency, which is not feasible for imaging human patients during a percutaneous procedure.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…These results also demonstrate the need for 3D strain imaging for complete tracking and measurement of the lesion volume. 29 Volume imaging of the ablation zone will reduce errors associated with area measurements. 29 The other limitations of this study include the use of a high transducer center frequency, which is not feasible for imaging human patients during a percutaneous procedure.…”
Section: Discussionmentioning
confidence: 99%
“…29 Volume imaging of the ablation zone will reduce errors associated with area measurements. 29 The other limitations of this study include the use of a high transducer center frequency, which is not feasible for imaging human patients during a percutaneous procedure. Ultrasound imaging was performed using an open-chest preparation with the transducer placed directly on the liver surface.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There is also Physiotherapy utilization [55] as the treatment of cervical pain [56] [57], its use in surgical and medical instruments (20 to 60 kHz) for dissection, ablation [58] [59], fragmentation and removal of biological tissue [60], activation of transplanted organs [61], biopsies [62] [63], vacuum biopsies [64], orthodontics [65], in obstetrics [66] and ambulatory gynecology [67] [68], pediatric anesthesia [69], forensic examinations [70] or simply to disinfect medical instruments [71].…”
Section: Introductionmentioning
confidence: 99%
“…There is no change in axial compression while recording each volume, but a small change in compression is applied between them. This compression can be achieved in a laboratory setting using an external fixture to compress the scanning subject [1,8,10,15,20,22] or, in the case of ablation imaging, by controlled movement of the ablation electrode [2]. More practically, the probe movement can be applied by hand [26].…”
Section: Introductionmentioning
confidence: 99%