2023
DOI: 10.21203/rs.3.rs-2630275/v1
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Three-Dimensional Femur Morphology Analysis for the Optimal Location of Subtrochanteric Osteotomy with an Implanted Wagner Cone Stem in Total Hip Arthroplasty for Crowe Type IV Developmental Dysplasia of the Hip

Abstract: Background This study aimed to accurately evaluate the matching of proximal and distal femoral segments and fitting of the femur–femoral stem in patients with Crowe type IV developmental dysplasia of the hip (DDH) who have undergone subtrochanteric osteotomy at different locations with an implanted Wagner cone stem to improve the rate of the bone union at the osteotomy site. Methods Three-dimensional femur morphology of 40 patients with Crowe type IV DDH was evaluated at each cross-section to determine the f… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…The combination of S‐ROM modular prosthesis in severe hip dysplasia patients proved more suitable for filling the femoral canal in comparison to single‐piece prostheses. This facilitated excellent torsional stability at the osteotomy site through the stabilization of the metaphyseal and diaphyseal osteotomy block 38,40 . Given the limited visual field in DAA, the modular S‐ROM system appeared to offer greater convenience in correcting abnormal femoral anteversion.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The combination of S‐ROM modular prosthesis in severe hip dysplasia patients proved more suitable for filling the femoral canal in comparison to single‐piece prostheses. This facilitated excellent torsional stability at the osteotomy site through the stabilization of the metaphyseal and diaphyseal osteotomy block 38,40 . Given the limited visual field in DAA, the modular S‐ROM system appeared to offer greater convenience in correcting abnormal femoral anteversion.…”
Section: Discussionmentioning
confidence: 99%
“…This facilitated excellent torsional stability at the osteotomy site through the stabilization of the metaphyseal and diaphyseal osteotomy block. 38,40 Given the limited visual field in DAA, the modular S-ROM system appeared to offer greater convenience in correcting abnormal femoral anteversion. The literature also reported there to be a trend towards the use of S-ROM prostheses, which is consistent with the clinical cases in this study.…”
Section: Prosthesis Analysismentioning
confidence: 99%