2020
DOI: 10.11607/jomi.8143
|View full text |Cite
|
Sign up to set email alerts
|

Three-Dimensional Finite Element Analysis of Different Implant Configurations in Enlarged First Molar Areas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 14 publications
0
12
0
Order By: Relevance
“…Some studies have reported the expression of STAT1 in RPMI-8226, NCI-H929, KMS-11, OPM-2, AMO-I, l-363, JJN-3, U266, MM.1S, KMS-20BM, and KMS-28BM MM cell lines (48)(49)(50). The prognostic role of related enzymes COX-2 and iNOS in MM and other malignancies has been reported (51). Other authors also discuss the involvement of STAT1, COX-2 and iNOS in all types of inflammation, angiogenesis, and metastasis of human cancer, chemical resistance and their special role in the development of drug resistance (52).…”
Section: Discussionmentioning
confidence: 99%
“…Some studies have reported the expression of STAT1 in RPMI-8226, NCI-H929, KMS-11, OPM-2, AMO-I, l-363, JJN-3, U266, MM.1S, KMS-20BM, and KMS-28BM MM cell lines (48)(49)(50). The prognostic role of related enzymes COX-2 and iNOS in MM and other malignancies has been reported (51). Other authors also discuss the involvement of STAT1, COX-2 and iNOS in all types of inflammation, angiogenesis, and metastasis of human cancer, chemical resistance and their special role in the development of drug resistance (52).…”
Section: Discussionmentioning
confidence: 99%
“…Figure 1 below showed the main aspects of the three different geometries under analysis. Before carrying out the real finite element analysis, it was necessary to simulate the abutment-implant contact [14] through the constraint functions present within the Software Inventor 2021, Autodesk (San Francisco, CA, USA) (Figures 2-4).…”
Section: Methodsmentioning
confidence: 99%
“…Figure 1 below showed the main aspects of the three different geometries under analysis. Before carrying out the real finite element analysis, it was necessary to simulate the abutment-implant contact [14] through the constraint functions present within the Software Inventor 2021, Autodesk (California, USA) (Figures 2-4). Regarding an internal connection, due to friction between the inclined planes of the implant and the abutment, the lateral occlusal force is concentrated on the implant wall through the abutment-implant connection zone.…”
Section: Methodsmentioning
confidence: 99%
“…In parallel, the biomechanics of the dental implant system, the subject of this review, are undergoing remarkable development. The adoption of 3D highresolution finite element analysis (FEA) allows identifying possible imperfections in the current implant system designs (51). Extension of digital technology to dental implant component manufacture enabling custom designs having better fit within the confines of the skeletal structure of the patient.…”
Section: Concluding Remarks and Future Outlookmentioning
confidence: 99%