2012
DOI: 10.1016/j.epsr.2012.01.001
|View full text |Cite
|
Sign up to set email alerts
|

Three-phase four-wire hybrid power filter using a smaller power converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
18
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(18 citation statements)
references
References 14 publications
0
18
0
Order By: Relevance
“…5. In this work the z-plane implementation of (10) is realised by applying the bilinear transform with frequency pre-warping to (12). This discretization method has been selected because it preserves, with relatively good accuracy, the resonant frequency and the phase margin of the original design in the "s" plane [26] [34].…”
Section: A Control System Designmentioning
confidence: 99%
See 3 more Smart Citations
“…5. In this work the z-plane implementation of (10) is realised by applying the bilinear transform with frequency pre-warping to (12). This discretization method has been selected because it preserves, with relatively good accuracy, the resonant frequency and the phase margin of the original design in the "s" plane [26] [34].…”
Section: A Control System Designmentioning
confidence: 99%
“…Other effects of imbalance are localised heating in machines and power converters, and reduced loadability of conventional synchronous generators (see [10] [11]) which affects the stability of the MGs [11]. The zero sequence current flowing through the neutral wire can produce additional problems such as overloading of the neutral conductor [9] [12] and malfunction of sensitive equipment due to ground voltage fluctuations if the current flowing through the neutral wire is large and/or the impedance of the neutral connection has a relatively large magnitude [9] [12]. In addition the load served by a 4-leg MG could be of nonlinear nature [12] [13] [14], generating distorted load currents which could also diminish the loadability of the power generating sources in the microgrid.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Some of the key practical limitations are as follows: Large amounts of harmonic current saturate or overload the filter and cause series resonance with the AC source, thereby resulting in excessive harmonic flow into the PFs. -PFs amplify source-side harmonic contents because of the impedance in the source of parallel and series negative resonances between the grid and the filter [29]. -The design parameters of PFs in an AC system depend on the system operating frequency, which changes around its nominal value according to variable load conditions.…”
Section: Introductionmentioning
confidence: 99%