2022
DOI: 10.11591/ijece.v12i6.pp5923-5937
|View full text |Cite
|
Sign up to set email alerts
|

Three-phase four-wire shunt hybrid active power filter model with model predictive control in imbalance distribution networks

Abstract: <span lang="EN-US">This paper presents a harmonic reduction and load imbalance model in a three-phase four-wire distribution network. This model uses a hybrid active power filter, a passive inductor and capacitor filter, and an active power filter in the form of a three-phase, four-leg connected grid inverter. The switching of the voltage source converter on this filter uses finite control set model predictive control (FCS-MPC). Control of this hybrid active power filter uses model predictive control (MP… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 32 publications
0
1
0
Order By: Relevance
“…This element of the UPS has an important functional purpose and in addition, provides many quality indicators, for example: low voltage total harmonic distortion (THD) when operating in inverter mode, high power factor and low level of DC voltage pulsations in rectifier mode [15]. To date, a number of studies of such bidirectional converters are known for use in various applications, for example, as a shunt active power filter [19] including for operation as part of UPS. One of the most in-depth studies can be called [20], where on the basis of more than 400 sources different versions of structures, algorithms of space-vector pulse-width modulation (SVPWM), control and application of these converters are presented.…”
Section: Introductionmentioning
confidence: 99%
“…This element of the UPS has an important functional purpose and in addition, provides many quality indicators, for example: low voltage total harmonic distortion (THD) when operating in inverter mode, high power factor and low level of DC voltage pulsations in rectifier mode [15]. To date, a number of studies of such bidirectional converters are known for use in various applications, for example, as a shunt active power filter [19] including for operation as part of UPS. One of the most in-depth studies can be called [20], where on the basis of more than 400 sources different versions of structures, algorithms of space-vector pulse-width modulation (SVPWM), control and application of these converters are presented.…”
Section: Introductionmentioning
confidence: 99%