2019
DOI: 10.1016/j.msec.2019.02.054
|View full text |Cite
|
Sign up to set email alerts
|

Thromboresistant semi-IPN hydrogel coating: Towards improvement of the hemocompatibility/biocompatibility of metallic stent implants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(10 citation statements)
references
References 75 publications
0
10
0
Order By: Relevance
“…SAED (Figure S2b, Supporting Information) and pXRD (Figure e) provided evidence for an amorphous‐to‐crystal transition, showing an increase in the reflections corresponding to both the (002) and (211) planes of HAP over time. The formation of HAP was further confirmed by the appearance of phosphate v 4 bending vibrations at 565 and 600 cm −1 at the expense of the broad band at 560 cm −1 (Figure S2c, Supporting Information) . The thermogravimetric and differential thermal analysis (TG/DTA) measurements (Figure f) revealed an endothermic peak between 20 and 200 °C and an exothermic peak between 200 and 400 °C, which are assigned to the loss of water and the decomposition of organics, respectively.…”
mentioning
confidence: 78%
“…SAED (Figure S2b, Supporting Information) and pXRD (Figure e) provided evidence for an amorphous‐to‐crystal transition, showing an increase in the reflections corresponding to both the (002) and (211) planes of HAP over time. The formation of HAP was further confirmed by the appearance of phosphate v 4 bending vibrations at 565 and 600 cm −1 at the expense of the broad band at 560 cm −1 (Figure S2c, Supporting Information) . The thermogravimetric and differential thermal analysis (TG/DTA) measurements (Figure f) revealed an endothermic peak between 20 and 200 °C and an exothermic peak between 200 and 400 °C, which are assigned to the loss of water and the decomposition of organics, respectively.…”
mentioning
confidence: 78%
“…Additionally, according to the Centers for Disease Control and Prevention, 30,100 CLABSI cases are reported every year in the intensive care units and acute care facilities of the US . As such, the development of a thromboresistant and antimicrobial catheter-coating material is of utmost importance. However, another consideration for the development of a catheter-coating material is to design a material that would form a “biocompatible system” when placed in the major vein. The term biocompatible has been defined as “the ability of a material to perform with an appropriate host response in a specific situation” . To explain in simpler terms, this means that a material is considered biocompatible if it does not elicit any adverse reactions in the living system.…”
Section: Introductionmentioning
confidence: 99%
“…Previous studies demonstrated that plasma exosomes helped improve ischemic stroke injury. [ 47,48 ] In this study, the use of DSPE to bridge exosomes could improve the biocompatibility and stability of exosomes compared with the direct encapsulation of exosomes with polymers, contributing to vascular remodeling. [ 4,17 ] This study represents a significant departure from previous work on ROS‐responsive exosome coatings, as exemplified by Hu et al.…”
Section: Discussionmentioning