Tibial anterior compartment compressibility in healthy subject, measured using compression sonography

Abstract: Introduction: Compression sonography has been introduced for non-invasive measurement of compartment compressibility and possible diagnostic tool for acute or chronic compartment syndrome in studies using human cadavers and animal models.To date, standard values in healthy subjects are not yet defined. The aim was to define standard compartment compressibility values in healthy human subjects and to assess the reliability of this measurement method. Methods: In 60 healthy volunteers, using ultrasound, the diam… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“… 4 Anwander et al showed that measurement of the anterior compartment compressibility ratio by compression sonography had high intraobserver and interobserver reliability. 2 Steinberg et al 48 showed significant differences in QMH measurement upon externally increased pressure of the superficial and deep posterior and anterior compartment. In 2011, Steinberg et al showed that QMH could predict an ICP >45 mm Hg in the anterior tibial compartment with 97% sensitivity and 74% specificity.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“… 4 Anwander et al showed that measurement of the anterior compartment compressibility ratio by compression sonography had high intraobserver and interobserver reliability. 2 Steinberg et al 48 showed significant differences in QMH measurement upon externally increased pressure of the superficial and deep posterior and anterior compartment. In 2011, Steinberg et al showed that QMH could predict an ICP >45 mm Hg in the anterior tibial compartment with 97% sensitivity and 74% specificity.…”
Section: Discussionmentioning
confidence: 99%
“…Diagnostic ICP criteria are based on generally weak studies. 2 , 51 Criteria suggested by Pedowitz et al, 33 Puranen and Alavaikko, 36 Styf and Körner, 49 or Aweid et al 3 still lack validity. Their use harbors the risk of a false diagnosis.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, Anwander et al investigated the reliability of a dual sensor approach in healthy volunteers [ 23 ]. Based on the methodology of PrUS, they demonstrated a significant and reliable approach to detect changes of a compression ratio (corresponding to RE) in 60 cases.…”
Section: Discussionmentioning