2004
DOI: 10.1002/jms.708
|View full text |Cite
|
Sign up to set email alerts
|

Ticlopidine quantification in human plasma by high‐performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study

Abstract: A rapid, sensitive and specific method to quantify ticlopidine in human plasma using clopidogrel as the internal standard (IS) is described. The analyte and the IS were extracted from acidified plasma by liquid-liquid extraction using diethyl ether-hexane (80 : 20, v/v). The extracts were analyzed by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry (HPLC/MS/MS). Chromatography was performed isocratically on a Jones Genesis C(8) 4 microm analytical column (150 x 4.1 mm i.d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0

Year Published

2005
2005
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(17 citation statements)
references
References 14 publications
0
17
0
Order By: Relevance
“…The liquid-liquid extraction method of Borges et al was adapted (20). One mL of each sample was introduced into a glass tube, followed by 15 µL of metoprolol tartrate (Sigma-Aldrich) as internal standard at a concentration of 15 µg/mL of and 200 µL of NaHCO 3 0.5 M. Samples were vortex-mixed for approximately 10 s. Ten mL of diethyl-ether were added to all tubes, which were shaken horizontally 30 min and then frozen for another 30 min at -80 ºC.…”
Section: Extraction Procedures For Carvedilolmentioning
confidence: 99%
“…The liquid-liquid extraction method of Borges et al was adapted (20). One mL of each sample was introduced into a glass tube, followed by 15 µL of metoprolol tartrate (Sigma-Aldrich) as internal standard at a concentration of 15 µg/mL of and 200 µL of NaHCO 3 0.5 M. Samples were vortex-mixed for approximately 10 s. Ten mL of diethyl-ether were added to all tubes, which were shaken horizontally 30 min and then frozen for another 30 min at -80 ºC.…”
Section: Extraction Procedures For Carvedilolmentioning
confidence: 99%
“…HPLC methods using a chiral stationary phase have been reported for the analysis of carvedilol enantiomers 6,7 . The clean-up procedures for the extraction of carvedilol from biological matrix consist of protein precipitation 5,6,10,12 , solid-phase extraction (SPE) 2,3,9 , liquid-liquid extraction (LLE) 6,7,[11][12][13] , combinations of protein precipitation with SPE 4 or combinations of LLE with back-extraction 1,8 . Those methods use a large amount of biological samples (0.15-1.0 mL plasma or 2-5 mL urine samples) in order to obtain the high sensitivity or include time-consuming extraction procedures and/or relatively long run time.…”
Section: Introductionmentioning
confidence: 99%
“…Carvedilol has been quantified in biological fluids using high-performance liquid chromatography (HPLC) with fluorescence [1][2][6][7][8][9][10][11] or electrochemical detector [12], mass spectrometry [13][14][15], hydrophilic interaction liquid chromatography (HILIC) with tandem mass spectrometry [16], capillary electrophoresis-ultra violet detector [17] and gas chromatography (GC)-MS detector [18]. The clean-up procedures for the extraction of carvedilol from biological matrix has been carried out by protein precipitation [8][9]13,15], solid-phase extraction (SPE) [2,6,12], liquid-liquid extraction (LLE) [10,14,18], combinations of protein precipitation with SPE [7] or combinations of LLE with back-extraction [1,11].…”
Section: Introductionmentioning
confidence: 99%
“…The clean-up procedures for the extraction of carvedilol from biological matrix has been carried out by protein precipitation [8][9]13,15], solid-phase extraction (SPE) [2,6,12], liquid-liquid extraction (LLE) [10,14,18], combinations of protein precipitation with SPE [7] or combinations of LLE with back-extraction [1,11]. However, these methods used a large volume of biological fluids (0.15-1.0 ml plasma or 2-5 ml urine), time-consuming pre-treat procedures for LLE, SPE or derivatization steps and required a long run-time (20 min) to obtain high sensitivity.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation